Class 12 Physics
6. Electromagnetic Induction · 6 / 14
⌕
Chapter 6 of 14

6. Electromagnetic Induction

12 sections · 12,520 words

Objectives

584 words · 3 min read

Unit II: Magnetism & Electromagnetic Induction

What you will learn

  • Explain the experiments of Faraday and Henry establishing electromagnetic induction.
  • State Faraday’s law of induction and Lenz’s law.
  • Derive the motional EMF induced across a conductor moving through a magnetic field (E = Bvl).
  • Derive self-inductance and mutual inductance expressions for solenoid configurations.
  • Explain eddy currents, their damping applications, and energy losses in transformer cores.
  • Derive the alternating EMF generated by a rotating coil in an AC generator (E = NBAω sin ωt).
Master every derivation in 4 uniform steps: Physical Setup, Starting Principle, Algebraic Progression, and Limiting Checks.
Prerequisite Bridge: 3-Minute Foundations Refresh - Magnetic Flux: ΦB=B⃗⋅A⃗=BAcos⁡θ\Phi_B = \vec{B}\cdot\vec{A} = BA\cos\theta. 1 Wb=1 T m21\,\mathrm{Wb} = 1\,\mathrm{T\,m^2}. - Calculus Derivative: ddtcos⁡(ωt)=−ωsin⁡(ωt)\frac{d}{dt}\cos(\omega t) = -\omega\sin(\omega t). Rate of change determines magnitude of induced EMF. - Lorentz Force on Free Charges: F⃗=q(v⃗×B⃗)\vec{F} = q(\vec{v} \times \vec{B}).

A bicycle lamp glows while the wheels turn, yet it carries no cell. A card opens a gate without touching it. A hob heats a pan through solid glass. One idea links all three: changing magnetic linkage can push charges.

You already know that currents make magnetic fields. This chapter runs the story backwards: changing magnetic conditions make electric effects. First you will meet the experiments, then the flux measure, then the two laws that size and direct every emf in this course.

The climb is gradual. It starts with the emf idea (6.1) and the classic experiments (6.2). Then it defines flux (6.3) and the rate law (6.4). Then it fixes directions and energy (6.5), moves conductors (6.6), coils with memory (6.7), and the generator (6.8). Each step uses only earlier steps.

Study actively. Cover each worked example, attempt it on paper, then compare line by line. When a practice answer disagrees with yours, the first line where your working leaves the printed one is exactly the idea to revise. Every number here has been recomputed by an independent program.

Expect two questions everywhere: how large, and which way. Size comes from rates and geometry; direction comes from the change. Answering them in that order keeps every section consistent.

Figures are part of the lesson, not decoration. Each graph is drawn from the printed formula, and each schematic labels exactly the quantities the text uses. Pause at every Read the figure box and trace it with a finger before moving on.

In 1831, Michael Faraday, an English experimenter, showed that changing magnetic conditions produce electric effects. His coil-and-magnet trials turned scattered observations into a reliable law. The exact day of each trial is retold loosely in popular accounts, so keep the year as the firm part and the sequence as the lesson.

Around the same time, Joseph Henry, an American physicist, reached similar results independently with powerful electromagnets. Histories differ on exact months, so the safe statement is independent work in the same period. His name survives in the henry, the unit of inductance in 6.7. Laboratory magnets of that period could already lift heavy loads, which made switched-current effects easy to demonstrate.

In 1834, Emil Lenz, a physicist working in Russia, stated the direction rule of 6.5. His rule gave the minus sign its physical meaning: the induced effect resists the change. It arrived only three years after the first induction trials, yet it settled direction debates that size formulas alone could not. Later generators and transformers, including the ideas behind 6.8, grew from these three contributions.

6.1 Discovery of Induction and Changing Flux

1,183 words · 5 min read

A bicycle lamp glows while the wheels turn, yet no cell hides inside. In this section you will learn why changing magnetism can replace a cell.

  • Electromotive force (emf) — work done per unit charge round a circuit, in volts.
  • Induced emf — emf produced by changing magnetic conditions, not by a cell.
  • Induced current — charge flow driven by an induced emf, in ampere.
  • Magnetic flux (preview) — how much magnetic field crosses a surface; defined fully in 6.3.
  • Flux linkage (preview) — flux times the number of coil turns; defined fully in 6.3.

A cell pushes charges by doing work on them. Emf means work per unit charge, measured in volts. It says how much energy each coulomb gains per trip round the circuit.

Current is different. Current means charge flow per unit time, measured in ampere. Emf is the push; current is the resulting motion. Mixing them up causes most early errors.

A coil can have emf without current. Leave its ends open and charges pile up at the terminals instead of flowing. Close the loop and the same emf drives a current. So ask for emf first, then ask whether a closed path lets current flow.

A meter also needs reading with care. A deflection shows current, which depends on resistance too. No deflection can mean no emf, or emf with an open break. Check the loop before concluding anything.

A strong magnet held still beside a coil gives no continuing deflection. Presence alone does nothing. What matters is whether the linked flux changes while you watch.

Three things can change that linkage. The field strength can rise or fall. The loop area can grow or shrink. The loop orientation can turn. Any one of them can induce emf; none of them needs motion of the whole coil.

Motion is one possible cause, not the definition. A fixed coil near a switched electromagnet feels changing flux with nothing moving. Conversely, sliding a rigid loop sideways through a uniform steady field changes nothing, so the net emf stays zero. Individual charges still feel magnetic forces, but they cancel round the loop.

A rigid closed coil slides sideways through a large uniform steady field. Its area and orientation stay fixed. Is its net induced emf nonzero?

Step 1 — goal. Decide whether linked flux changes during the slide.

Step 2 — rule. Emf needs changing linked flux, not mere motion.

Step 3 — apply. Field, area and orientation all stay fixed, so flux stays fixed.

Step 4 — result. The rate of change is zero, hence no net emf. Motion without flux change induces nothing.

Result: The net emf is zero. Look for flux change, not motion.

Keep the field fixed and the loop position fixed, but squeeze the loop smaller. Its area shrinks, so its linked flux shrinks with it. An emf appears during the squeeze and stops when the squeezing stops.

Stretching works the same way in reverse. Any deformation that changes area changes linkage. Shape alone is never the test; area times field alignment is.

A circular loop sits in a steady uniform field normal to its plane. It is squeezed quickly into a smaller circle, then held. When does emf appear?

Step 1 — goal. Timing of the emf, not its size.

Step 2 — rule. Emf follows the rate of linkage change.

Step 3 — squeeze. Area falls, so flux falls: emf present during the squeeze.

Step 4 — hold. Area fixed again: emf zero afterwards.

Step 5 — check. A faster squeeze gives a larger emf for the same area drop.

Result: Emf appears only while the shape changes. Start and stop of change bracket the emf.

Cut a small gap in the loop and repeat the push. The changing flux still sets up emf, and charge piles at the cut faces. No charge flows across the gap, so heating stays zero. Probes across the gap read the emf while an ammeter in series reads nothing.

This split explains confusing meter readings. Zero current can mean zero emf or an open path. Nonzero emf with zero current is normal, not a fault. Check continuity before declaring induction absent.

A centre-zero meter is the honest detector here. It swings either way from rest, so direction shows directly. A single-sided meter would hide reversals and invite wrong conclusions.

SituationLinked fluxEmf
Magnet held still near coilFixedNone after transients
Magnet pushed towards coilChangingPresent during motion
Loop squeezed in a steady fieldChanging areaPresent during squeeze
Loop slid sideways in uniform fieldFixedZero net

Read the table. Each row varies one thing and holds the rest fixed. Only rows with changing linkage show emf. Use it to test any new claim before calculating.

coilmeter: 0NSheld still
No flux change, no deflection (schematic). A fixed magnet gives a fixed flux, so the meter rests at zero.

Read the figure. The left box is the coil and the circle is the meter. Two wires join them into a closed loop. The bar on the right stays fixed, so the flux stays fixed. The needle points straight up at zero. If the bar moved, the needle would kick during the motion only.

⚡ Quick Check Flashcards3 questions

Cover the answers. Try each question on paper first. If an answer differs from yours, find the step where your working left the printed one.

Question 1
A magnet rests beside a coil for a minute. The meter reads zero throughout. Does this prove magnets cannot induce emf?
Try answering before revealing!
Question 2
A coil with open ends sits in a changing field. Can it have emf with no current? Explain.
Try answering before revealing!
Question 3
A loop is pulled sideways through a uniform steady field with fixed shape. What is its net emf and why?
Try answering before revealing!
Common mistake: Do not replace “changing flux” with “a magnetic field is present”.

  1. What does a zero meter reading prove about emf?
  2. Name three linkage changes that can induce emf.
  3. A hand moves a coil through a uniform field without deforming it. Must emf appear?
Click to reveal Quick Check answers
1. Only that no current flows; an open break or balanced forces can also give zero. Check the loop first. 2. Field strength, loop area, and loop orientation relative to the field. 3. No. If flux linkage stays fixed, the net emf stays zero.

6.2 The Experiments of Faraday and Henry

1,178 words · 5 min read

A swipe card opens a gate with no cell inside the card. In this section you will repeat the experiments that first revealed induction.

  • Galvanometer — a sensitive current detector; its needle kicks during a transient current.
  • Relative motion — movement of one part as seen from another; only the change in linkage matters.
  • Primary coil — the coil whose current is switched or varied.
  • Secondary coil — the neighbouring coil where emf is detected.
  • Transient — a brief response that dies away after conditions settle.

Wire a coil to a sensitive meter. Push a magnet towards it and the needle kicks during the push. Hold the magnet still and the needle falls back to zero after the circuit settles. Pull the magnet away and the needle kicks the other way.

Speed matters for size. A faster push changes flux faster and gives a larger emf. The current also depends on resistance and on the coil inductance, which slows fast changes. So compare emf histories, not just meter kicks, when judging two pushes.

Either end can lead. Pushing the north pole in gives one sign; pushing the south pole in reverses the field direction and the response. What counts is the signed flux history for your chosen normal, not which hand moved.

Hold the magnet fixed and move the coil towards it. The linkage history can match the earlier push, so a similar transient appears. Relative motion decides the flux history; absolute motion of one named part does not.

Still, do not assume every motion matches. Turning the coil changes orientation flux, while sliding it sideways in a uniform field may change nothing. Compare actual flux histories before predicting equal currents.

Place two coils side by side. Power the first through a switch and wire the second to a meter. Neither coil moves at all. Close the switch and the meter kicks while the first current grows.

Open the switch and the meter kicks the other way while the field collapses. Leave the primary current steady and the secondary rests at zero after the transient. A steady current makes a steady field, and steady flux induces nothing.

This version matters for technology. Card readers, induction hobs and transformers all use changing currents rather than moving magnets. The physics is one rule; the engineering picks the convenient cause.

A primary current rises slowly, stays steady, then falls rapidly. Describe the secondary emf in the three intervals.

Step 1 — goal. Linkage behaviour in each interval.

Step 2 — rule. Secondary emf follows the rate of change of linkage.

Step 3 — rise. Slow rise means small emf one way.

Step 4 — steady. Flat current means zero emf after the transient.

Step 5 — fall. Rapid fall means larger emf the opposite way.

Step 6 — sanity check. Faster change gives larger magnitude, and steady means silent, as observed.

Result: Emf is small during the rise, zero when steady, and larger and reversed during the rapid fall. Rate and direction both follow the linkage history.

A north pole is pushed into a coil, then pulled out at the same speed. A second trial pushes a south pole in at the same speed. Compare the three kicks.

Step 1 — goal. Relative size and direction of three deflections.

Step 2 — in versus out. Same speed with opposite change: equal size, opposite direction.

Step 3 — north versus south. A reversed pole reverses the field history: equal size, opposite direction to the north-in kick.

Step 4 — check. Three trials but only two directions; speed sets size while the change sets sign.

Result: Equal speeds give equal-size kicks. Any reversal of the change flips the direction.

Card readers use the same physics without moving magnets. The reader drives a changing current in its own coil. The card coil answers with its own transient, which the reader decodes. Motion, switching, or a passing card all reduce to one linkage history.

Reversing the primary instead of switching it off doubles the swing. The current runs from full forward to full reverse, so the flux change is twice the switch-off drop. Fast large reversals are exactly how induction hobs drive strong heating with small coils.

Transients die because circuits settle. Resistance turns the extra energy to heat while inductance resists sudden jumps. After a few electrical time scales the secondary rests at zero under steady primary current. Section 6.7 names that time scale.

coil Pcell + switchcoil Smeterfield
Neighbouring coils with no motion (schematic). Switching the left current changes the flux through the right coil.

Read the figure. The left coil connects to a cell and switch; the right coil connects to a meter. Thin arrows show the field crossing from left to right. Closing the switch grows that field, so the right meter kicks once. Nothing moves; the current change does all the work.

ActionLinkageMeter
Push magnet inRises while movingKick one way
Hold everything fixedSteadyReturns to zero
Pull magnet outFalls while movingKick the other way
Switch neighbour on or offJumps during changeTransient kick

Read the table. Each row pairs an action with its linkage and the meter result. The second row is the key control: steady conditions mean silence. Use it to isolate real induction from stray kicks.

⚡ Quick Check Flashcards3 questions

Try each question yourself before reading the answers. Show the rule, the substitution and the units in your working.

Question 1
A magnet is pushed in slowly, then pulled out fast. Compare the two kicks.
Try answering before revealing!
Question 2
The primary current is steady for a minute. What does the secondary meter read, and why?
Try answering before revealing!
Question 3
The coil is moved instead of the magnet with the same linkage history. What changes in the prediction?
Try answering before revealing!
Common mistake: A detector measures current, so its reading also depends on resistance and transient dynamics.

  1. Why does switching a nearby coil matter?
  2. Why does reversing the magnet pole reverse the response?
  3. A steady primary current flows for an hour. What emf appears in the secondary after the first instant?
Click to reveal Quick Check answers
1. Switching changes its current and hence the magnetic flux through the detector coil. 2. It reverses the sign of the flux change for the same chosen area normal. 3. None. Steady flux after the transient means zero induced emf.

6.3 Magnetic Flux

1,144 words · 5 min read

A window facing the sun gathers more light than one seen edge-on. In this section you will measure how a magnetic field crosses a surface.

  • Magnetic flux — the surface integral of B over an area; its unit is the weber (Wb).
  • Area normal — an arrow perpendicular to a surface that fixes the sign convention.
  • Weber (Wb) — the SI unit of flux; one weber equals one tesla square metre.
  • Flux linkage — flux through one turn times the number of turns.

For a small flat patch, dΦB=B⋅dAd\Phi_B=\mathbf B\cdot d\mathbf A. The vector dAd\mathbf A points along the local normal. Add the contributions over the surface: ΦB=∫B⋅dA\Phi_B=\int\mathbf B\cdot d\mathbf A.

For a uniform field and a flat area the integral simplifies to ΦB=BAcos⁡θ\Phi_B=BA\cos\theta. The angle is measured from the normal, not from the loop plane. Flux is a signed scalar: its sign follows the chosen normal direction.

Flux has unit weber, with 1 Wb=1 T m21\ \mathrm{Wb}=1\ \mathrm{T\,m^2}. A field running along the plane contributes zero. A field along the normal gives the largest magnitude for fixed strength and area. For curved surfaces or nonuniform fields, use the integral rather than averaged guesses.

A side-view sketch is enough to define the flux angle.
Draw it in an exam: Draw the loop, then a perpendicular area-normal arrow. Label the angle between that arrow and B. Use dots for a field out of the page and crosses for a field into the page.
The normal is perpendicular to the loop. Only the B component along the normal contributes to flux.

Read the plot. The horizontal line is the loop seen edge-on. The vertical arrow is the normal. The tilted arrow is B. The angle marked between the normal and B is the theta in the cosine. Measure from the plane instead and you need the complement.

Read the 3D view. The flat square is the area. The vertical arrow is the normal. The tilted arrow is B. Drag the view and confirm that only the normal component of B threads the square. The caption states the same rule in words.

A coil with identical turns has linkage N times the flux through one turn. Do not confuse flux per turn with total linkage. If different turns enclose different fluxes, add their individual linkages instead of multiplying.

Linkage earns its keep in multi-turn coils. A ten-turn coil in a changing millitesla field can out-signal a single large loop. Designers add turns instead of area when space is tight. The N factor is cheap voltage.

Each turn of a 4040-turn coil links 0.003,mathrmWb0.003,mathrm{Wb}. Find the total linkage.

Step 1 — goal. From per-turn flux to coil linkage.

Step 2 — rule. Add identical turns: linkage =N×=N\times(flux per turn).

Step 3 — substitute. 40×0.003=0.1240\times0.003=0.12.

Step 4 — attach the unit. Weber-turns, since turns count the linkings.

Result: The linkage is 0.12 Wb-turns. Turns multiply a shared flux.

A flat loop has area 0.015 m20.015\,\mathrm{m^2} in a 0.32 T0.32\,\mathrm T uniform field. Its normal makes 60∘60^\circ with the field. Find the flux.

Step 1 — goal. Flux through one flat loop in a uniform field.

Step 2 — rule. ΦB=BAcos⁡θ\Phi_B=BA\cos\theta with theta from the normal.

Step 3 — check geometry. Theta is 60∘60^\circ from the normal, so cos⁡60∘=0.5\cos60^\circ=0.5.

Step 4 — substitute with units. ΦB=(0.32 T)×(0.015 m2)×0.5\Phi_B=(0.32\ \mathrm T)\times(0.015\ \mathrm{m^2})\times0.5.

Step 5 — multiply. 0.32×0.015=0.00480.32\times0.015=0.0048, then 0.0048×0.5=0.00240.0048\times0.5=0.0024.

Step 6 — attach the unit. Flux comes out in T m2\mathrm{T\,m^2}, which is the weber.

Step 7 — sanity check. Half the face-on value 0.0048 Wb0.0048\ \mathrm{Wb}, as a 60∘60^\circ tilt demands.

Result: The flux is 0.0024 Wb. Tilt halves the face-on value here.

Face-on gives the full product. Edge-on gives zero because the field runs along the surface. A tilt between them scales by the cosine. Reversing the chosen normal flips the sign but leaves the physics unchanged, since the circulation convention flips with it.

A spinning coil sweeps through every row of the table each turn. Face-on, tilted, edge-on, tilted, face-on again: the flux follows the cosine round the cycle. The generator section replays this table as a sine wave.

A loop of area 0.020 m20.020\,\mathrm{m^2} sits in a uniform 0.50 T0.50\,\mathrm T field. Find the flux with its normal parallel to B, then with its plane parallel to B.

Step 1 — goal. Two orientations of the same loop.

Step 2 — face-on rule. Φ=BA\Phi=BA when the normal lines up with B.

Step 3 — substitute. Φ=(0.50 T)×(0.020 m2)=0.01 Wb\Phi=(0.50\ \mathrm T)\times(0.020\ \mathrm{m^2})=0.01\ \mathrm{Wb}.

Step 4 — edge-on rule. B lies in the plane, so no component crosses.

Step 5 — result. Flux 0.01 Wb face-on and zero edge-on.

Result: Face-on flux is 0.01 Wb; edge-on flux is zero. Orientation decides; strength alone does not.

OrientationCosine factorFlux
Normal along B1Full BA
Normal at 60° to B0.5Half BA
B in the loop plane0Zero

Read the table. Each row fixes an orientation, its cosine and the result. The middle row matches the worked tilt. Use it to estimate before calculating.

⚡ Quick Check Flashcards3 questions

Work these on paper with the answers hidden. If your result disagrees with the printed one, compare the steps one by one until the paths divide.

Question 1
A 0.020 m20.020\,\mathrm{m^2} loop faces a 0.50 T0.50\,\mathrm T field with its normal tilted 60∘60^\circ from B. Find the flux.
Try answering before revealing!
Question 2
B lies in the plane of a flat loop in a uniform field. What is the flux? Explain without numbers.
Try answering before revealing!
Question 3
The chosen normal is reversed. What happens to the signed flux and to the physics?
Try answering before revealing!
Common mistake: The angle in the cosine is measured from the normal, not from the loop plane.

  1. What is the flux when B lies in the loop plane?
  2. State the SI unit of flux and its base combination.
  3. Two turns enclose different fluxes. How is total linkage found?
Click to reveal Quick Check answers
1. Zero for a uniform field and a flat loop. 2. Weber; one tesla square metre. 3. Add the individual turn fluxes; do not multiply one value by N.

6.4 Faraday's Law of Induction

1,110 words · 5 min read

An induction hob boils a pan faster on a higher setting. In this section you will turn the rate of flux change into volts.

  • Faraday’s law — induced emf equals the negative rate of change of flux linkage.
  • Average emf — finite linkage change divided by the time interval.
  • Instantaneous emf — the derivative value at one instant.
  • Lenz’s direction step — choosing the emf sign from the change; used fully in 6.5.

Pick a positive area normal and use the right-hand rule for positive circulation. For one turn, E=−dΦB/dt\mathcal E=-d\Phi_B/dt. For identical turns, E=−N dΦB/dt\mathcal E=-N\,d\Phi_B/dt. For a finite interval the average is −NΔΦB/Δt-N\Delta\Phi_B/\Delta t.

The derivative gives an instantaneous value. The finite difference gives an average over its interval. Do not present an average as the value at one instant unless the rate is uniform. State which one the question asks for.

Compute magnitude first, then fix direction. Find the size from the rate, then use the circulation rule or Lenz’s law for the sign. Splitting the job this way prevents most sign errors. Magnitude from the rate; direction from Lenz.

Work in two passes: size from the rate formula, then sign from the direction rule. Never let an uncertain sign corrupt the magnitude step.

Model ramp matching the worked coil example. The rise slope gives the emf; the flat part gives zero emf.

Read the figure. The curve shows total linkage climbing steadily to 0.864 Wb-turns at 0.30 s, then lying flat. The slope of the rise is 0.864 divided by 0.30, which is 2.88 V. The flat part has zero slope, so zero emf. Steeper means larger; flat means silent.

A stationary 160160-turn coil of area 0.012 m20.012\,\mathrm{m^2} has its normal parallel to B. The field rises uniformly by 0.45 T0.45\,\mathrm T in 0.30 s0.30\,\mathrm s. Find the emf magnitude.

Step 1 — goal. Average emf during a uniform rise.

Step 2 — rule. ∣E∣=NA∣ΔB∣/Δt|\mathcal E|=NA|\Delta B|/\Delta t for fixed area and orientation.

Step 3 — substitute with units. ∣E∣=160×(0.012 m2)×(0.45 T)÷(0.30 s)|\mathcal E|=160\times(0.012\ \mathrm{m^2})\times(0.45\ \mathrm T)\div(0.30\ \mathrm s).

Step 4 — multiply. 160×0.012=1.92160\times0.012=1.92; 1.92×0.45=0.8641.92\times0.45=0.864.

Step 5 — divide by time. 0.864÷0.30=2.880.864\div0.30=2.88.

Step 6 — attach the unit. Volt, since weber per second is a volt.

Step 7 — direction note. The induced field opposes the increase (full argument in 6.5).

Step 8 — sanity check. Matches the graph slope above, as it must for the same numbers.

Result: The emf magnitude is 2.88 V. A uniform rate gives one constant emf.

A 5050-turn coil of area 0.030 m20.030\,\mathrm{m^2} sits normal to a 0.40 T0.40\,\mathrm T field. The coil is withdrawn quickly so its linkage falls to zero in 0.25 s0.25\,\mathrm s. Find the average emf magnitude.

Step 1 — goal. Average emf during complete withdrawal.

Step 2 — rule. ∣E∣=N×(initial linkage)÷Δt|\mathcal E|=N\times(\text{initial linkage})\div\Delta t.

Step 3 — initial linkage. 50×0.40×0.030=20×0.030=0.60 Wb-turns50\times0.40\times0.030=20\times0.030=0.60\ \mathrm{Wb\text{-}turns}.

Step 4 — divide. 0.60÷0.25=2.40.60\div0.25=2.4.

Step 5 — sanity check. Withdrawing in half the time would double this, since the same drop over less time steepens the slope.

Result: The average emf is 2.4 V. Faster exit means larger emf.

A 2525-turn coil of area 0.030 m20.030\,\mathrm{m^2} sits with its normal along a 0.40 T0.40\,\mathrm T field. It is turned 90∘90^\circ in 0.20 s0.20\,\mathrm s so its plane ends parallel to B. Find the average emf magnitude.

Step 1 — goal. Average emf during a pure orientation change.

Step 2 — start and end flux. Start: Φ=BA=0.40×0.030=0.012 Wb\Phi=BA=0.40\times0.030=0.012\ \mathrm{Wb} per turn. End: plane parallel to B, so zero.

Step 3 — linkage drop. 25×0.012=0.30 Wb-turns25\times0.012=0.30\ \mathrm{Wb\text{-}turns}.

Step 4 — divide. 0.30÷0.20=1.5 V0.30\div0.20=1.5\,\mathrm V.

Step 5 — condition. Field and area stayed fixed; only orientation changed, which the cosine carries.

Result: The average emf is 1.5 V. Turning works like withdrawing, with the cosine doing the falling.

A changing magnetic field creates a circulating electric field. Its line integral round a stationary loop need not vanish. Unlike an electrostatic potential difference, this emf cannot come from a single-valued potential alone.

A voltmeter reads whatever its leads link, not only the part across its terminals. In a changing field, dangling leads add their own loop emf. Twist the leads together and keep them clear of the changing region for an honest reading.

Average and instantaneous emf part ways under uneven rates. A triangular flux pulse gives a stepped emf: steady slope means steady emf, and sharp corners mean jumps. Quote the interval with every average; quote the instant with every derivative.

What changesUseCondition
Uniform B rise, fixed coilNA times dB/dtNormal fixed, turns identical
Coil withdrawn from fieldN times linkage drop over timeCount only linked turns
Smooth flux functionDerivative at the instantQuote as instantaneous only

Read the table. Each row names a situation, its formula and the condition beside it. Check the condition before substituting.

⚡ Quick Check Flashcards3 questions

Cover the answers. Try each question on paper first. If an answer differs from yours, find the step where your working left the printed one.

Question 1
A 200200-turn coil loses 0.003 Wb0.003\,\mathrm{Wb} per turn in 0.15 s0.15\,\mathrm s. Find the average emf magnitude.
Try answering before revealing!
Question 2
At one instant the flux through a loop is zero. Must the emf be zero then? Explain.
Try answering before revealing!
Question 3
A coil current is computed as emf divided by resistance. Name one hidden assumption.
Try answering before revealing!
Common mistake: Do not multiply by the number of turns twice when the given quantity is already total flux linkage.

  1. Which emf uses a finite flux difference divided by time?
  2. State Faraday’s law for N identical turns.
  3. A rate doubles while the interval halves for the same drop. What happens to average emf?
Click to reveal Quick Check answers
1. The average emf over that interval. 2. Emf equals minus N times the rate of change of flux per turn. 3. It doubles, since the same change over less time steepens the slope.

6.5 Lenz's Law and Conservation of Energy

1,285 words · 6 min read

A magnet dropped through a copper tube falls slowly, as if through syrup. In this section you will learn the direction rule that explains the braking.

  • Lenz’s law — the induced effect opposes the change in linked flux.
  • Induced field — the magnetic field of the induced current itself.
  • Viewing side — the face from which clockwise is judged; always state it.
  • Energy source — the external work that supplies the induced heating.

Lenz’s law says the induced current produces a magnetic effect that resists the change in linkage. If outward flux grows, the induced field points inward. If outward flux weakens, the induced field points outward. It is the change that is opposed, not always the original field.

  • Choose a viewing side and state whether the external flux points towards or away from you.
  • Decide whether that flux is increasing or decreasing.
  • Choose the induced field that resists that change.
  • Curl the fingers of your right hand for current with the thumb along the induced field.

Fix the viewing side first. The same physical loop looks clockwise from one face and anticlockwise from the other. Every direction answer must name its viewing side, or it cannot be marked right.

Imagine the opposite rule. A moving magnet induces a current that pulls it in faster with no supply. Both motion energy and heating grow from nothing. That free gain never happens.

The opposing effect prevents it. Pushing the magnet in fights a repulsion; holding it against the pull while withdrawing also takes work. An external agent supplies the work, which reappears as electrical energy and heat. The minus sign in Faraday’s law is energy conservation in symbols.

A vivid demo compares two tubes. Drop a magnet through a copper tube and it drifts down slowly. Drop it through a plastic tube of the same size and it falls fast. The plastic is an insulator, so no swirl currents form and no braking appears.

The copper slows the fall without touching the magnet. At a steady slow speed the upward magnetic push carries most of the weight. The lost height energy reappears as heat in the tube wall.

SNvloopBinoutinduced Bcross is into page; dot is out
N pole pushed into a loop, seen from the side (schematic). The induced field points back towards the magnet.

Read the figure. The magnet moves right towards the loop. Field arrows enter the loop to the right and grow. The heavy arrow inside points left: the induced field resists the increase. Cross on the left edge and dot on the right edge mark the resulting current sense. Reversing the motion would flip every arrow.

Viewed from above, the upward magnetic flux through a loop is decreasing. Find the induced current direction.

Step 1 — viewing side. From above; upward means towards the viewer.

Step 2 — change. Upward flux is decreasing.

Step 3 — induced field. To resist the loss, it points upward too.

Step 4 — right hand. Thumb up needs anticlockwise current seen from above.

Step 5 — cross-check. Seen from below the same loop reads clockwise, which is why the viewing side is part of the answer.

Result: The current is anticlockwise viewed from above. Decreasing flux draws a supporting field.

The north pole of a magnet is pushed into a coil. Give the induced current sense and name the energy source for the heating.

Step 1 — flux. Rightward flux through the coil increases.

Step 2 — induced field. It points left, opposing the increase.

Step 3 — sense. Right-hand rule gives the cross-left and dot-right pattern in the figure.

Step 4 — energy. The hand pushing against the repulsion does work; that work feeds the heating.

Step 5 — check. Withdrawing the magnet reverses the change, so the current and the force direction both flip.

Result: The coil pushes back on the magnet, and the pushing hand supplies the energy. Opposition plus work explains the heat.

A loop with flux +BA+BA is flipped 180circ180^circ in a steady uniform field. Describe the flux history and the emf timing.

Step 1 — start. Flux +BA+BA with the normal along the field.

Step 2 — middle. At 90∘90^\circ the plane lies along the field, so flux zero.

Step 3 — end. At 180∘180^\circ the normal points against the field: flux −BA-BA.

Step 4 — timing. The flux falls throughout the flip, so emf flows one way during the flip and stops after.

Step 5 — check. Total swing 2BA2BA exceeds any 90∘90^\circ turn, which suits a quick flip.

Result: The flip gives ==one transient covering a 2BA2BA swing. Half a turn moves twice the quarter-turn flux.==

External fluxChangeInduced field
UpwardIncreasingDownward
UpwardDecreasingUpward
Into pageIncreasingOut of page
Into pageDecreasingInto page

Read the table. Each row pairs a flux direction and its change with the resisting field. Cover the last column and reproduce it; that is the whole law.

⚡ Quick Check Flashcards3 questions

Try each question yourself before reading the answers. Show the rule, the substitution and the units in your working.

Question 1
Upward flux through a loop increases. Give the induced current viewed from above.
Try answering before revealing!
Question 2
A magnet is pulled out of a coil at steady speed. Who supplies the energy that heats the coil?
Try answering before revealing!
Question 3
A student says the induced field always opposes the external field. Give a counter-case.
Try answering before revealing!
Common mistake: Always state the viewing direction before writing clockwise or anticlockwise.
Sign Convention & Direction Watch: Lenz’s Law & Conservation of Energy The induced EMF in a closed circuit always opposes the change in magnetic flux that creates it: E=−dΦBdt\mathcal{E} = -\frac{d\Phi_B}{dt} - Opposing Flux Rule: - If external flux ΦB\Phi_B is INCREASING: Induced current generates a magnetic field OPPOSING the external field. - If external flux ΦB\Phi_B is DECREASING: Induced current generates a magnetic field REINFORCING the external field. - Right-Hand Grip Rule: Curl the fingers of your right hand in the direction of induced current; your thumb points along the induced magnetic field B⃗ind\vec{B}_{\rm ind}.
Conceptual Trap & Exam Pitfall: Lenz’s Law is Newton’s Third Law for Magnetic Systems If Lenz’s law had a positive sign, an initial movement would induce a current that accelerated the magnet further, generating infinite kinetic energy and electrical power from zero external work, completely violating the First Law of Thermodynamics.

  1. Does Lenz’s law always make the induced field opposite to the external field?
  2. What supplies heating energy when a magnet is pushed steadily into a resistive coil?
  3. A loop spins in a steady field with no circuit change except orientation. Which law gives the emf sign?
Click to reveal Quick Check answers
1. No. During decreasing flux it can point the same way to support the change. 2. The mechanical work of the external agent pushing against the induced repulsion. 3. Faraday’s law with the chosen circulation, read through the Lenz direction steps.

6.6 Motional Electromotive Force

1,341 words · 6 min read

A conductor sliding on rails can light a bulb with no cell in sight. In this section you will compute that motional emf and balance its energy.

  • Motional emf — emf from a conductor moving through a magnetic field.
  • Lorentz force — the magnetic push felt by a charge moving through a field.
  • Sliding-rod circuit — rails plus a moving rod whose loop area sweeps out flux.
  • Open-circuit voltage — terminal voltage with no current path.
  • Eddy currents (preview) — swirl currents in bulk metal; met fully in 6.7.

A charge qq moving with velocity v\mathbf v in field B\mathbf B feels qv×Bq\mathbf v\times\mathbf B. In a rod, the free charges get dragged with it and pile towards one end.

For a straight rod of length ll with rod, velocity and uniform field mutually perpendicular, the motional emf magnitude is BlvBlv. Charge separation builds an electric field until the open-circuit electric and magnetic forces balance. State the perpendicular condition beside every use.

Polarity comes from a positive test charge. Point the fingers along v, curl towards B, and the thumb gives the push on positive charge. Electrons move the other way. That one check fixes which end is positive.

In the open rod the pile-up stops growing when the electric push balances the magnetic push. The terminal voltage then equals Blv exactly in the ideal case. No current flows, so no drag appears and no work is needed to hold the motion.

rodminusplusvF opposes vIIB outdots mean field out of page
Sliding rod on rails with the field out of the page (schematic). The rod polarity, current and opposing force all follow from one direction check.

Read the figure. The dots mark B out of the page. The rod moves right with v. Positive charge is pushed down, so the bottom reads plus and the top minus. Current arrows run round the fixed rails. The heavy arrow on the rod points left: the magnetic force on the current opposes the motion.

A 0.40 m0.40\,\mathrm m rod moves at 2.5 m s−12.5\,\mathrm{m\,s^{-1}} in a 0.60 T0.60\,\mathrm T perpendicular field. The closed circuit resistance is 3.0 Ω3.0\,\Omega. Ignore inductive transients. Find emf, current and mechanical power.

Step 1 — goal. Emf, then current, then the force and power balance.

Step 2 — emf rule. ∣E∣=Blv|\mathcal E|=Blv for the perpendicular case.

Step 3 — substitute with units. ∣E∣=(0.60 T)×(0.40 m)×(2.5 m s−1)|\mathcal E|=(0.60\ \mathrm T)\times(0.40\ \mathrm m)\times(2.5\ \mathrm{m\,s^{-1}}).

Step 4 — multiply. 0.60×0.40=0.240.60\times0.40=0.24; 0.24×2.5=0.60.24\times2.5=0.6.

Step 5 — current. I=∣E∣/R=0.6÷3.0=0.2 AI=|\mathcal E|/R=0.6\div3.0=0.2\,\mathrm A.

Step 6 — opposing force. F=BIl=0.60×0.2×0.40=0.048 NF=BIl=0.60\times0.2\times0.40=0.048\,\mathrm N.

Step 7 — mechanical power. Fv=0.048×2.5=0.12 WFv=0.048\times2.5=0.12\,\mathrm W.

Step 8 — heating check. I2R=(0.2)2×3.0=0.12 WI^2R=(0.2)^2\times3.0=0.12\,\mathrm W, matching FvFv.

Step 9 — sanity check. Units close as volts, ampere, newton, watt; energy is conserved, not created.

Result: Emf 0.6 V, current 0.2 A, opposing force 0.048 N, power 0.12 W. Push power equals heat power.

The flux view agrees. If the rod advances by dxdx, loop area grows by l dxl\,dx, so ∣dΦB/dt∣=Bl dx/dt=Blv|d\Phi_B/dt|=Bl\,dx/dt=Blv. With steady speed and negligible inductance, I=Blv/RI=Blv/R, the opposing force is BIlBIl, and external power Fv=IE=I2RFv=I\mathcal E=I^2R. Two routes, one answer.

A rod rotating about one end in a perpendicular field has different speeds at different radii. Adding the local contributions Bωr drB\omega r\,dr from the axis to length ll gives Bωl2/2B\omega l^2/2. Do not use the tip speed for the whole rod.

Sweeping a large radius at modest spin can beat sliding a short rod fast. Compare B times the swept area per second in each design. Area per second is the fair race, not tip speed alone.

Push the rod at an angle and only the crossing speed counts. Sliding along its own length changes almost no area. Resolve v into crossing and sliding parts, then use the crossing part in Blv.

Real rails add friction and contact resistance. Friction demands extra push beyond the magnetic drag. Contact resistance joins the loop total. Ideal formulas give the floor; friction and contacts add the rest.

A 0.50 m0.50\,\mathrm m rod rotates about one end at 12 rad s−112\,\mathrm{rad\,s^{-1}} in a perpendicular 0.30 T0.30\,\mathrm T field. Find the emf between its ends.

Step 1 — goal. Emf between centre and tip of a rotating rod.

Step 2 — rule. ∣E∣=Bωl2/2|\mathcal E|=B\omega l^2/2 for rotation about one end.

Step 3 — substitute. ∣E∣=0.30×12×0.502÷2|\mathcal E|=0.30\times12\times0.50^2\div2.

Step 4 — compute. 0.502=0.250.50^2=0.25; 0.30×12=3.60.30\times12=3.6; 3.6×0.25=0.93.6\times0.25=0.9; 0.9÷2=0.450.9\div2=0.45.

Step 5 — sanity check. Less than Blvtip=0.30×0.50×6.0=0.90 VBlv_{\rm tip}=0.30\times0.50\times6.0=0.90\ \mathrm V, since inner parts move slower.

Result: The end-to-end emf is 0.45 V. Average speed is half the tip speed.

SetupEmfCurrent
Isolated moving rodBlv between endsZero; charge piles up
Rod sliding on closed railsBlv drives the loopBlv over R
Rod rotating about one endHalf of tip-speed valueNeeds a closed return path

Read the table. Each row pairs a setup with its emf and current. The first row has voltage without flow. The third row warns against using tip speed everywhere.

⚡ Quick Check Flashcards3 questions

Work these on paper with the answers hidden. If your result disagrees with the printed one, compare the steps one by one until the paths divide.

Question 1
A 0.20 m0.20\,\mathrm m rod slides at 2.0 m s−12.0\,\mathrm{m\,s^{-1}} normal to a 0.70 T0.70\,\mathrm T field. Find the motional emf.
Try answering before revealing!
Question 2
The sliding circuit above has total resistance 4.0 Ω4.0\,\Omega. Find the current and the opposing force.
Try answering before revealing!
Question 3
The rails are disconnected so the rod moves alone. What changes for emf and current?
Try answering before revealing!
Common mistake: A magnetic force does no work on a charge total velocity; the moving mechanical system supplies the electrical energy.

1. Physical Setup & Coordinate Frame: A conducting rod of length ll slides with constant velocity vv along frictionless parallel rails in a uniform perpendicular magnetic field BB.

2. Governing Principle: Free conduction electrons inside the moving rod experience magnetic Lorentz force F⃗m=−e(v⃗×B⃗)\vec{F}_m = -e(\vec{v} \times \vec{B}).

3. Algebraic Progression & Approximations: 1. The magnetic force drives electrons toward one end of the rod, establishing an electric field E⃗\vec{E} along the rod length. 2. In steady state, electric force balances magnetic force: eE=evB  ⟹  E=vBe E = e v B \implies E = v B 3. Potential difference (induced EMF) across rod of length ll: E=∫0lE dl=vBl\mathcal{E} = \int_0^l E\,dl = v B l 4. Alternative derivation via flux linkage: In time Δt\Delta t, rod sweeps area ΔA=l(vΔt)\Delta A = l(v\Delta t). Change in flux ΔΦB=BΔA=BlvΔt\Delta \Phi_B = B\Delta A = B l v \Delta t. 5. By Faraday’s law: ∣E∣=ΔΦBΔt=Bvl|\mathcal{E}| = \frac{\Delta \Phi_B}{\Delta t} = B v l

4. Limiting Cases & Sanity Check: If v⃗\vec{v} is parallel to B⃗\vec{B} or to rod length, E=0\mathcal{E} = 0. Maximum motional EMF occurs when v⃗,B⃗\vec{v}, \vec{B}, and conductor length are mutually orthogonal.

  1. Which rule fixes the positive end of a moving isolated rod?
  2. A sliding loop moves at steady speed against magnetic drag. Where does the heat come from?
  3. When does Blv fail as written?
Click to reveal Quick Check answers
1. The direction of v cross B for a positive test charge. 2. The external push: its power Fv equals the resistor heating. 3. When rod, velocity and field are not mutually perpendicular; use the component form instead.

6.7 Inductance

1,528 words · 7 min read

A doorbell transformer hums with no moving parts. In this section you will learn how coils link each other, store energy, and brake metal without contact.

  • Self-inductance (L) — flux linkage per unit own current, in henry.
  • Mutual inductance (M) — secondary linkage per unit primary current, in henry.
  • Henry (H) — the SI unit of inductance; one henry gives one volt per ampere per second.
  • Back emf — self-induced emf opposing current change.
  • Eddy currents — loop currents inside bulk conductors.
  • Time constant — the L over R scale for current growth and decay.

For fixed linear magnetic geometry, the secondary linkage from primary current is N2Φ21=MI1N_2\Phi_{21}=MI_1. Then E2=−M dI1/dt\mathcal E_2=-M\,dI_1/dt, with sign set by the winding senses. M depends on turns, geometry, separation and core material.

For ideal coaxial long solenoids sharing area AA and length ll, M=μ0N1N2A/lM=\mu_0N_1N_2A/l. An iron core raises linkage far above the air value by guiding flux. State the ideal shape condition beside each use.

core guides the fluxprimary N1secondary N2B in core follows I1I1 changesemf2 answers
Two coils sharing one core (schematic). The primary change sends flux through the core and links the secondary.

Read the figure. The bar is the shared core. Three loops on the left form the primary; three on the right form the secondary. The heavy arrow shows core flux following the primary current. A change on the left links the right and drives its emf. More secondary turns mean more linkage.

Two fixed coils have M=0.006 HM=0.006\,\mathrm H. The primary current changes by 4.0 A4.0\,\mathrm A in 0.050 s0.050\,\mathrm s. Find the average secondary emf magnitude.

Step 1 — goal. Average secondary emf from a primary ramp.

Step 2 — rule. ∣E2∣=M∣ΔI1∣/Δt|\mathcal E_2|=M|\Delta I_1|/\Delta t.

Step 3 — slope. ∣ΔI1∣/Δt=4.0÷0.050=80 A s−1|\Delta I_1|/\Delta t=4.0\div0.050=80\ \mathrm{A\,s^{-1}}.

Step 4 — multiply. 0.006×80=0.480.006\times80=0.48.

Step 5 — sanity check. Millihery coupling with tens of ampere per second gives sub-volt emf, as expected.

Result: The average secondary emf is 0.48 V. Steeper primary ramps drive larger secondary emf.

A coil own linkage is LILI in the same linear approximation. Its self-induced emf is −L dI/dt-L\,dI/dt. Inductance measures electrical inertia: larger L means stronger opposition to rapid change.

A long air-core solenoid of NN turns, area AA and length ll has L=μ0N2A/lL=\mu_0N^2A/l when end effects are negligible. Doubling turns quadruples L, since turns count once in field and once in linkage.

An 0.080 H0.080\,\mathrm H coil current rises from zero to 3.0 A3.0\,\mathrm A in 0.020 s0.020\,\mathrm s. Find the average back-emf magnitude and the final stored energy.

Step 1 — goal. Back-emf during the rise, then stored energy at the end.

Step 2 — slope. ΔI/Δt=3.0÷0.020=150 A s−1\Delta I/\Delta t=3.0\div0.020=150\ \mathrm{A\,s^{-1}}.

Step 3 — back-emf. L×150=0.080×150=12 VL\times150=0.080\times150=12\ \mathrm V, opposing the rise.

Step 4 — energy rule. U=LI2/2U=LI^2/2.

Step 5 — substitute. U=0.080×9.0÷2=0.36 JU=0.080\times9.0\div2=0.36\ \mathrm J.

Step 6 — sanity check. The emf is large because the rise is fast; the energy depends only on the final current, not its speed.

Result: Back-emf 12 V and stored energy 0.36 J. Speed sets emf; final current sets energy.

Building the current from zero needs work dW=LI dIdW=LI\,dI. Adding from 00 to II gives U=LI2/2U=LI^2/2. In a uniform vacuum field the energy density is B2/(2μ0)B^2/(2\mu_0). Real resistive coils also dissipate heat; not all supplied energy is stored.

Stored energy waits in the field and returns when current falls; dissipated heat never returns. Inductance explains the delay, resistance explains the loss.

A changing flux through bulk metal drives loop currents with no wires. These eddy currents follow Lenz’s law like any induced current. Their fields oppose the change, so a moving plate near a magnet feels a drag force. Maglev brakes and smooth train brakes use this contact-free drag.

The same swirls waste energy as heat in transformer cores and meter discs. Thin laminated sheets break the loops and cut the loss. Choose solid metal for braking and laminations for efficient cores.

metal plateplate movesNSmagnet fixedswirls oppose the changedrag
Eddy-current braking of a moving plate (schematic). The swirls oppose the motion that creates them.

Read the figure. The magnet stays fixed while the plate slides right. Two swirl loops appear under the magnet. The heavy arrow on the plate points left: drag opposing the motion. Sliding faster strengthens the swirls and the drag together.

A coil in series with resistance RR and a steady source approaches I0=V/RI_0=V/R gradually. With I0I_0 as target, I=I0(1−e−t/τ)I=I_0(1-e^{-t/\tau}) on switch-on and I=I0e−t/τI=I_0e^{-t/\tau} on switch-off, where τ=L/R\tau=L/R. Larger L means slower response; larger R means faster settling.

Model growth and decay with time constant 0.02 s (L = 0.12 H, R = 6 ohm). After one time constant the rise reaches 63 percent and the fall keeps 37 percent.

Read the figure. The rising curve starts at zero and bends towards 2 A. The falling curve starts at 2 A and bends towards zero. At one time constant the rise has covered 63 percent and the fall keeps 37 percent. Five time constants count as settled for most purposes.

A 600600-turn solenoid of length 0.30 m0.30\,\mathrm m has core area 4.0 cm24.0\,\mathrm{cm^2} of air. Find L. Then a 0.12 H0.12\,\mathrm H coil in series with 6.0 Ω6.0\,\Omega aims at 2.0 A2.0\,\mathrm A: find the time constant and the switch-on current after one time constant.

Step 1 — convert area. 4.0 cm2=4.0×10−4 m24.0\ \mathrm{cm^2}=4.0\times10^{-4}\ \mathrm{m^2}.

Step 2 — solenoid rule. L=μ0N2A/lL=\mu_0N^2A/l for a long coil.

Step 3 — compute. L=0.603×10−3 HL=0.603\times10^{-3}\,\mathrm H, about 0.60 mH0.60\ \mathrm{mH}.

Step 4 — time constant. τ=L/R=0.12÷6.0=0.02 s\tau=L/R=0.12\div6.0=0.02\ \mathrm s.

Step 5 — one-tau current. I=2.0×(1−e−1)=2.0×0.632=1.264 AI=2.0\times(1-e^{-1})=2.0\times0.632=1.264\ \mathrm A.

Step 6 — decay check. Switching off from 2.0 A2.0\ \mathrm A would leave 2.0×e−1=0.736 A2.0\times e^{-1}=0.736\ \mathrm A after one tau.

Result: The solenoid is about 0.603 mH and the circuit time constant is 0.02 s. Turns squared set L; L over R sets the speed.

Five time constants count as settled because the gap shrinks below one percent. Waiting longer changes little. Quote five taus in answers that ask when a transient is over.

Opening a switch on a large inductor can spark. The collapsing current forces a brief high voltage across the gap. That spark wastes energy and warns that real inductive circuits need care.

SituationInductor behaviourEnergy
Steady DC through ideal LZero emf; plain wireStored LI squared over 2
Fast riseLarge back emfSource works harder
Bulk metal in changing fluxEddy swirlsDrag plus heat

Read the table. Each row pairs a situation with behaviour and energy fate. The first row is the calm reference; the other rows show change in action.

⚡ Quick Check Flashcards3 questions

Cover the answers. Try each question on paper first. If an answer differs from yours, find the step where your working left the printed one.

Question 1
A primary ramps 3.0 A3.0\,\mathrm A in 0.10 s0.10\,\mathrm s past a secondary with M=0.020 HM=0.020\,\mathrm H. Find the average secondary emf.
Try answering before revealing!
Question 2
Find the energy in a 0.050 H0.050\,\mathrm H coil carrying 4.0 A4.0\,\mathrm A.
Try answering before revealing!
Question 3
A transformer core is built from insulated sheets instead of one block. Explain the choice.
Try answering before revealing!
Common mistake: Back emf opposes change in current, not necessarily the current itself.
Conceptual Trap & Exam Pitfall: Inductance is Purely Geometric Self-inductance L=μ0n2AlL = \mu_0 n^2 A l and mutual inductance M=μ0n1n2AlM = \mu_0 n_1 n_2 A l depend solely on geometry, number of turns, and core permeability—independent of the instantaneous current II flowing through the coils.

  1. Does an ideal inductor oppose a steady DC current through an induced emf?
  2. Which ideal solenoid quantity grows as the square of turn count?
  3. After five time constants, is an LR rise settled?
Click to reveal Quick Check answers
1. No. Its self-induced emf is zero once its current is steady. 2. Its self-inductance, for unchanged area and length. 3. For most purposes yes; the gap to target has shrunk below one percent.

6.8 AC Generator

1,256 words · 6 min read

Dam turbines spin day and night to feed the grid. In this section you will derive the sine wave that rotation produces.

  • AC generator — a rotating coil that converts mechanical work into alternating emf.
  • Slip rings and brushes — contacts that pass the rotating ends to the fixed circuit.
  • Peak emf — the sine amplitude NBAωNBA\omega for the ideal coil.
  • Alternating emf — voltage that reverses sign every half turn.
  • Load torque — the magnetic drag that the driving agent must overcome.

Let the area normal of a uniform NN-turn coil rotate at angular speed ω\omega in uniform B. If its normal is parallel to B at t=0t=0, per-turn flux is ΦB=BAcos⁡ωt\Phi_B=BA\cos\omega t. Differentiating gives E=NBAωsin⁡ωt\mathcal E=NBA\omega\sin\omega t. Peak emf is E0=NBAω\mathcal E_0=NBA\omega.

A different starting angle changes phase, not amplitude. It shifts the curve sideways while the peak stays fixed. Frequency follows rotation alone; turns, area and field only scale the height.

Model sine wave for the worked generator (peak 24 V, one turn shown). Read peak, zero and sign directly off the curve.

Read the figure. The curve starts at zero, peaks at a quarter turn, crosses zero at half, troughs at three quarters, and returns. Peak reads 24 V and trough minus 24 V. The marked zero at half turn is where flux momentarily peaks.

position Aposition BNSn along Bmax flux, emf 0NSn across Bzero flux, max emfquarter turn apart
Two coil positions a quarter turn apart (schematic). Flux and emf peak at opposite positions.

Read the figure. Position A shows the coil face-on: maximum flux and zero slope, so zero emf. Position B, a quarter turn later, shows the coil edge-on: zero flux with steepest change, so maximum emf. Rotation direction fixes the sign.

Emf is greatest when flux passes through zero because its slope is steepest there. Emf vanishes when flux is maximum or minimum. Maximum flux and maximum emf sit a quarter-cycle apart. Memorise that pairing and half the generator questions answer themselves.

Slip rings connect the rotating ends to the fixed circuit without twisting the wires. Brushes keep sliding contact. This ideal model ignores winding resistance, friction and uneven field shape. Real machines add those losses on top.

Split rings belong to the next device family, not here. A generator uses continuous slip rings so the output keeps alternating. Mixing up the two rings is a common exam slip; the rings decide the waveform shape.

Frequency and amplitude answer different questions. Count zero crossings per second for frequency; read the tallest point for amplitude. A faster spin raises both together, while extra turns raise only the height.

A shared grid fixes one frequency for all its stations, so every generator on it must spin in step. Amplitude is then set by design turns and field. That split keeps devices compatible across stations.

A 120120-turn coil of area 0.020 m20.020\,\mathrm{m^2} rotates at 40 rad s−140\,\mathrm{rad\,s^{-1}} in 0.25 T0.25\,\mathrm T. Find the emf amplitude.

Step 1 — goal. Peak emf of the ideal rotating coil.

Step 2 — rule. E0=NBAω\mathcal E_0=NBA\omega.

Step 3 — substitute with units. E0=120×(0.25 T)×(0.020 m2)×(40 rad s−1)\mathcal E_0=120\times(0.25\ \mathrm T)\times(0.020\ \mathrm{m^2})\times(40\ \mathrm{rad\,s^{-1}}).

Step 4 — multiply. 120×0.25=30120\times0.25=30; 30×0.020=0.6030\times0.020=0.60; 0.60×40=240.60\times40=24.

Step 5 — sanity check. Tens of volts from a hand-scale coil at moderate speed: plausible for a demonstration generator.

Result: The peak emf is 24 V. Spin faster or add turns to raise it.

For the generator above, find the instantaneous emf when the coil has turned 30∘30^\circ from the zero-emf position.

Step 1 — goal. Sine value partway to the peak.

Step 2 — rule. E=E0sin⁡ϕ\mathcal E=\mathcal E_0\sin\phi with ϕ\phi from the flux-maximum position.

Step 3 — substitute. E=24×sin⁡30∘=24×0.5\mathcal E=24\times\sin30^\circ=24\times0.5.

Step 4 — compute. 24×0.5=12 V\times0.5=12\ \mathrm V.

Step 5 — check. Between zero and peak, as a 30∘30^\circ position must be.

Result: The emf is 12 V. ==Halfway in angle is not halfway in sine, but 30∘30^\circ is exactly half.==

For the worked generator spinning at 40,mathrmrad,s−140,mathrm{rad,s^{-1}}, find the output frequency and period.

Step 1 — goal. How often the sine repeats, and one-turn time.

Step 2 — frequency rule. f=ω/2πf=\omega/2\pi.

Step 3 — substitute. f=40÷6.2832=6.37 Hzf=40\div6.2832=6.37\,\mathrm{Hz}.

Step 4 — period. T=2π/ω=6.2832÷40=0.1571 sT=2\pi/\omega=6.2832\div40=0.1571\,\mathrm s.

Step 5 — check. f×T=6.37×0.1571≈1f\times T=6.37\times0.1571\approx1, as any frequency-period pair must.

Result: The output is 6.37 Hz with period 0.1571 s. Spin rate sets the repeat, not the size.

A loaded generator current produces a torque opposing the rotation. Holding speed then needs mechanical power. Raising speed raises both amplitude and frequency; adding turns raises amplitude at fixed frequency. Choose the knob that matches the need.

PositionFluxEmf
Face-on to BMaximumZero
Quarter turn onZeroMaximum
Half turn onMinimumZero

Read the table. Each row is a snapshot of the spin. Flux and emf never peak together. Cover one column and recite it from the other two.

⚡ Quick Check Flashcards3 questions

Try each question yourself before reading the answers. Show the rule, the substitution and the units in your working.

Question 1
A 100100-turn coil of area 0.025 m20.025\,\mathrm{m^2} spins at 60 rad s−160\,\mathrm{rad\,s^{-1}} in 0.20 T0.20\,\mathrm T. Find the peak emf.
Try answering before revealing!
Question 2
Flux through the spinning coil is momentarily maximum. What is the emf then, and why?
Try answering before revealing!
Question 3
A loaded generator slows unless pushed harder. Explain in energy terms.
Try answering before revealing!
Common mistake: Maximum flux and maximum emf occur a quarter-cycle apart.

Phase relationship between magnetic flux Φ_B = Φ_max cos(ωt) and induced EMF E = E_max sin(ωt) in an AC generator.

Key Graph Features (Slope, Intercept & Asymptotes): Induced EMF is proportional to the negative derivative of flux: E=−dΦB/dt=NBAωsin⁡(ωt)\mathcal{E} = -d\Phi_B/dt = NBA\omega\sin(\omega t). When coil plane is perpendicular to B⃗\vec{B} (ωt=0\omega t = 0), flux is maximum, but rate of flux change is zero (E=0\mathcal{E} = 0). When coil plane is parallel to B⃗\vec{B} (ωt=π/2\omega t = \pi/2), flux is zero, but rate of cutting field lines is maximum (E=Emax⁡\mathcal{E} = \mathcal{E}_{\max}). EMF leads flux by 90∘90^\circ in phase.

  1. What fixes the frequency in this simple two-pole generator model?
  2. Why does adding turns at fixed speed raise amplitude but not frequency?
  3. Slip rings wear out. What job were they doing?
Click to reveal Quick Check answers
1. The coil rotation frequency. 2. Turns scale linkage height; only rotation speed sets how fast it repeats. 3. Passing the rotating coil ends to the fixed external circuit without twisting the leads.

Summary

297 words · 1 min read

This chapter turned changing magnetism into calculable emf. Work down this list and tick each line you can honestly do. Revisit the named section for any line you cannot.

  • Explain why only changing linkage induces emf, with three causes. (6.1)
  • Describe the magnet-coil and two-coil experiments and their transients. (6.2)
  • Use ΦB=BAcos⁡θ\Phi_B=BA\cos\theta with the angle from the normal, and linkage NΦBN\Phi_B. (6.3)
  • Use E=−N dΦB/dt\mathcal E=-N\,d\Phi_B/dt for magnitude and average, then fix direction. (6.4)
  • Apply the four Lenz steps and explain the minus sign by energy. (6.5)
  • Use ∣E∣=Blv|\mathcal E|=Blv with its perpendicular condition and balance Fv=I2RFv=I^2R. (6.6)
  • Use E2=−M dI1/dt\mathcal E_2=-M\,dI_1/dt, EL=−L dI/dt\mathcal E_L=-L\,dI/dt, U=LI2/2U=LI^2/2 and τ=L/R\tau=L/R. (6.7)
  • Use E0=NBAω\mathcal E_0=NBA\omega and place flux and emf peaks a quarter-cycle apart. (6.8)

Three facts deserve a final look. Emf follows the rate of flux change, never the flux value. Direction answers need a viewing side plus an increase-or-decrease verdict. And every formula here carries a condition — uniform field, fixed orientation, linear core, negligible resistance — so quote the condition with the rule.

QuantityUnitCondition
Flux linkageWb-turnsNormal fixed per turn
Average emfVFinite interval quoted
Motional emfVPerpendicular geometry
InductanceHLinear core region
Peak generator emfVSteady rotation speed

Read the table. Each row pairs a chapter quantity with its unit and its condition. Cover the last column and recite it from memory; that habit prevents most formula errors.

Keep this chapter habit: magnitude first, direction second, units always. The flux language of surfaces and normals returns in later physics, and the fluency built here pays off there.

Use the equations with their assumptions, sign conventions and units. Explain each symbol before substituting values.

Points to Ponder

137 words · 1 min read

  • Induction answers to flux change; a huge steady field alone induces nothing. Before calculating, name what is changing.
  • Emf can exist without current; current needs a closed conducting path as well. An open gap reads voltage while passing nothing.
  • The normal and the positive circulation form one linked convention; flipping the normal flips both signs together. Physics stays put while bookkeeping turns.
  • The minus sign is energy conservation: the induced effect resists the change that feeds it. Any prediction of self-driving gain has an error.
  • Test each answer against limits: zero rate means zero emf, quarter-cycle shifts swap peaks, and doubling the rate doubles the emf. A result that fails an obvious limit is being misused.
Core conceptual traps from these points to ponder are integrated directly inline inside the relevant topic sections.

Exercises

1,477 words · 7 min read

Master these questions in four structured tiers matching the CBSE board exam blueprint. Try every problem on paper before checking the answered solutions below.

6.MCQ.1 A copper ring is held horizontally and a bar magnet is dropped through the ring with its north pole pointing downward. The downward acceleration of the magnet is: (a) Equal to g; (b) Greater than g; (c) Less than g; (d) Zero.

6.MCQ.2 The self-inductance of a solenoid of length l and cross-sectional area A with N turns is: (a) μ₀ N A / l; (b) μ₀ N² A / l; (c) μ₀ N² A l; (d) μ₀ N A l.

Each question consists of two statements: Assertion (A) and Reason (R). Choose: (a) Both A and R are true and R is correct explanation of A; (b) Both A and R are true but R is NOT correct explanation; (c) A is true, R is false; (d) A is false, R is true.

6.AR.1 Assertion (A): Eddy currents are minimized by using laminated magnetic cores rather than solid metal blocks in transformers. Reason (R): Thin laminations insulated with varnish break the continuous conduction loops, increasing electrical resistance and reducing I²R eddy current power losses. Choose: (a) Both A and R are true and R is correct explanation of A; (b) Both A and R are true but R is NOT correct explanation; (c) A is true, R is false; (d) A is false, R is true.

6.AR.2 Assertion (A): When a metallic plate swings between magnetic pole pieces, it rapidly comes to rest. Reason (R): Electromagnetic damping occurs due to eddy currents induced in the swinging plate opposing its motion. Choose: (a) Both A and R are true and R is correct explanation of A; (b) Both A and R are true but R is NOT correct explanation; (c) A is true, R is false; (d) A is false, R is true.

Case-Based Assessment — Induction Cooktops: An induction cooking stove utilizes an alternating magnetic field to heat cooking vessels with high efficiency. A coil situated beneath a glass-ceramic surface carries an alternating current of frequency f = 25 kHz. (i) Explain the mechanism by which heat is generated in the bottom of a steel pan. (ii) Why does the glass surface of the cooktop stay relatively cool during operation? (iii) Why does an aluminum or copper pan fail to heat effectively on a standard induction cooktop?

6.1 A coil and a magnet stay fixed relative to each other for a minute. Must the meter show a continuing current?

6.2 Distinguish emf from current in one sentence each.

6.3 Find the flux when B=0.28 TB=0.28\,\mathrm T and A=0.020 m2A=0.020\,\mathrm{m^2} with the normal parallel to B.

6.4 A 0.025 m20.025\,\mathrm{m^2} loop has its normal at 60∘60^\circ to a 0.44 T0.44\,\mathrm T field. Find the flux.

6.5 A 120120-turn coil loses 0.006 Wb0.006\,\mathrm{Wb} per turn in 0.30 s0.30\,\mathrm s. Find the average emf magnitude.

6.6 Upward flux through a loop increases. Give the induced current viewed from above, with the reason.

6.7 Upward flux through a loop decreases. Give the induced current viewed from above, with the reason.

6.8 A 0.25 m0.25\,\mathrm m rod moves at 1.6 m s−11.6\,\mathrm{m\,s^{-1}} normal to a 0.90 T0.90\,\mathrm T field. Find the motional emf magnitude.

6.9 The rod above feeds a circuit of total resistance 4.5 Ω4.5\,\Omega. Find the current and the heating power.

6.10 A 0.40 m0.40\,\mathrm m rod rotates about one end at 8.0 rad s−18.0\,\mathrm{rad\,s^{-1}} in a perpendicular 0.50 T0.50\,\mathrm T field. Find the end-to-end emf.

6.11 An inductor current falls at 5.0 A s−15.0\,\mathrm{A\,s^{-1}} and L=0.20 HL=0.20\,\mathrm H. Find the induced emf magnitude and state its tendency.

6.12 Find the energy stored in a 0.060 H0.060\,\mathrm H coil carrying 5.0 A5.0\,\mathrm A.

6.13 A long solenoid keeps its shape but doubles its turns. How does L change, and why?

6.14 For M=0.015 HM=0.015\,\mathrm H and a primary slope of 8.0 A s−18.0\,\mathrm{A\,s^{-1}}, find the secondary emf magnitude.

6.15 An LR circuit aims at 3.0 A3.0\,\mathrm A with τ=0.020 s\tau=0.020\,\mathrm s. Find the switch-on current after one time constant.

6.16 A generator has N=60N=60, B=0.40 TB=0.40\,\mathrm T, A=0.020 m2A=0.020\,\mathrm{m^2} and ω=75 rad s−1\omega=75\,\mathrm{rad\,s^{-1}}. Find the peak emf.

6.17 Generator flux is maximum at some instant. Is the emf maximum then? Explain with slope.

6.18 Explain why a loaded generator does not create energy from nothing.

6.19 A metal sheet swings between magnet poles and stops quickly with no contact. Explain in two steps.

6.20 An LR circuit carries 2.5 A2.5\,\mathrm A when its source is removed. With τ=0.020 s\tau=0.020\,\mathrm s, find the current after one time constant.

Answers

6.MCQ.1 (c) By Lenz’s law, the induced current in the ring produces an upward magnetic repulsive force opposing the falling magnet, making a<ga < g.

6.MCQ.2 (b) L=μ0n2Al=μ0(N/l)2Al=μ0N2A/lL = \mu_0 n^2 A l = \mu_0 (N/l)^2 A l = \mu_0 N^2 A / l.

6.AR.1 (a) Both A and R are true, and Reason correctly explains the physical prevention of bulk eddy current loops.

6.AR.2 (a) Both A and R are true, and Reason describes magnetic damping used in galvanometer dead-beat mechanisms.

(i) The high-frequency alternating current generates a rapidly oscillating vertical magnetic field (25 kHz25\,\mathrm{kHz}). By Faraday’s law, this induces strong circular eddy currents in the ferromagnetic base of the steel pan; Joule heating (I2RI^2 R) and magnetic hysteresis losses rapidly heat the pan. (ii) Glass is an insulator with zero mobile conduction electrons; no eddy currents are induced in the ceramic surface, so it heats only secondarily by contact with the hot pot. (iii) Aluminum and copper are non-ferromagnetic with very low electrical resistivity; although eddy currents are induced, the low resistance yields small I2RI^2 R heat dissipation and negligible magnetic hysteresis, failing to heat effectively.

6.1 No. After transients, unchanged linked flux gives no induced emf. Only a change during the observation window can drive a sustained reading.

6.2 Emf is work supplied per unit charge round a path. Current is charge flow per unit time through a cross-section. An open coil can hold the first with none of the second.

6.3 Face-on rule Φ=BA\Phi=BA: 0.28×0.0200.28\times0.020. Multiply: 28×20=56028\times20=560, placed at four decimals gives 0.0056 Wb0.0056\,\mathrm{Wb}. Full alignment gives the full product, so any tilt would only reduce this.

6.4 Φ=BAcos⁡60∘=0.44×0.025×0.5\Phi=BA\cos60^\circ=0.44\times0.025\times0.5. First 0.44×0.025=0.0110.44\times0.025=0.011; halved gives 0.0055 Wb0.0055\,\mathrm{Wb}. Tilt halves the face-on value, exactly as the cosine demands.

6.5 Total drop =120×0.006=0.72 Wb-turns=120\times0.006=0.72\ \mathrm{Wb\text{-}turns}. Divide: 0.72÷0.30=2.4 V0.72\div0.30=2.4\,\mathrm V. The same drop in 0.15 s0.15\ \mathrm s would double this, since the slope would steepen.

6.6 Clockwise. The induced field must point downward to resist the increase. Thumb-down curls clockwise as seen from above.

6.7 Anticlockwise. The induced field points upward to support the dying flux. Thumb-up curls anticlockwise as seen from above.

6.8 ∣E∣=Blv=0.90×0.25×1.6|\mathcal E|=Blv=0.90\times0.25\times1.6. First 0.90×0.25=0.2250.90\times0.25=0.225; then 0.225×1.6=0.36 V0.225\times1.6=0.36\,\mathrm V. Perpendicular geometry assumed throughout, as the formula demands.

6.9 Current I=0.36÷4.5=0.08 AI=0.36\div4.5=0.08\,\mathrm A. Power P=IE=0.08×0.36=0.0288 WP=I\mathcal E=0.08\times0.36=0.0288\,\mathrm W. An external push must supply exactly this power, or the rod would slow down.

6.10 ∣E∣=Bωl2/2=0.50×8.0×0.16÷2|\mathcal E|=B\omega l^2/2=0.50\times8.0\times0.16\div2. First 0.50×8.0=4.00.50\times8.0=4.0; then 4.0×0.16=0.644.0\times0.16=0.64; halved gives 0.32 V0.32\,\mathrm V. Inner parts move slower than the tip, which the half accounts for.

6.11 ∣E∣=L×slope=0.20×5.0=1 V|\mathcal E|=L\times\mathrm{slope}=0.20\times5.0=1\,\mathrm V. Its direction tends to maintain the falling current, resisting the decrease rather than the current itself.

6.12 U=LI2/2=0.060×25÷2=0.75 JU=LI^2/2=0.060\times25\div2=0.75\,\mathrm J. Doubling the current would quadruple this, while doubling the inductance would only double it.

6.13 It grows by four times. Turns count once in the field and once in the linkage, so N2N^2 carries a factor 22=42^2=4 in the linear air-core formula.

6.14 ∣E2∣=M×slope=0.015×8.0=0.12 V|\mathcal E_2|=M\times\mathrm{slope}=0.015\times8.0=0.12\,\mathrm V. A steeper primary ramp scales this proportionally, while a steady primary gives nothing.

6.15 I=3.0×(1−e−1)=3.0×0.632I=3.0\times(1-e^{-1})=3.0\times0.632. Multiply: 3.0×0.632=1.8963.0\times0.632=1.896, printed as 1.896 A1.896\,\mathrm A. About 63 percent of target, as one tau demands.

6.16 E0=NBAω=60×0.40×0.020×75\mathcal E_0=NBA\omega=60\times0.40\times0.020\times75. First 60×0.40=2460\times0.40=24; then 24×0.020=0.4824\times0.020=0.48; then 0.48×75=36 V0.48\times75=36\,\mathrm V. Speed sets frequency as well as height, while turns set only height.

6.17 No. At maximum flux the curve is flat, so its slope is zero. Emf follows the slope, hence peaks a quarter-cycle away.

6.18 Its current produces an opposing magnetic torque. External mechanical work against that torque supplies the output energy plus losses.

6.19 Motion changes the linked flux, driving eddy swirls. Their fields oppose the motion by Lenz, so kinetic energy turns to heat and the swing dies.

6.20 Decay follows I=I0e−t/τI=I_0e^{-t/\tau}. After one tau, I=2.5×e−1=2.5×0.368I=2.5\times e^{-1}=2.5\times0.368. Multiply: 2.5×0.368=0.9202.5\times0.368=0.920, printed as 0.92 A0.92\,\mathrm A. About 37 percent remains, mirroring the 63 percent rise.

Up next