5. Magnetism and Matter
Objectives
Unit II: Magnetism & Electromagnetic Induction
What you will learn
- Describe the magnetic dipole moment of an orbiting electron and define the Bohr magneton.
- Derive the magnetic field of a bar magnet at axial and equatorial points by magnetic dipole analogy.
- State Gauss’s law for magnetism (∮ B·dA = 0) and explain the non-existence of isolated magnetic monopoles.
- Distinguish between magnetic field B, magnetisation M, and magnetic intensity H.
- Classify diamagnetic, paramagnetic, and ferromagnetic materials by susceptibility χ and relative permeability μ_r.
- Explain Curie’s law for paramagnets and the magnetic domain mechanism of ferromagnetism.
A fridge magnet holds a note without any battery. A compass needle turns on its own. A clinic scanner sees inside the body with magnetism alone. This chapter explains all three with one idea: matter contains tiny magnetic moments, and their arrangement decides what a sample does.
You already know moving charges create magnetic fields from the previous chapter. Here the charges stay inside atoms, yet their loops still act as magnets. First you will model one small magnet as a dipole. Then you will add up many atomic moments into bulk quantities. Finally you will sort materials by how they respond.
The chapter climbs in small steps. It starts with poles and compasses (5.1). Then it treats the bar magnet as a dipole with field, torque and energy rules (5.2). Then it states the flux law of magnetism (5.3). Then it builds the bulk quantities M, H and susceptibility (5.4). Finally it explains diamagnetic, paramagnetic and ferromagnetic behaviour (5.5).
Study actively. Cover each worked example, attempt it on paper, then compare line by line. When a practice answer disagrees with yours, the first line where your working leaves the printed one is exactly the idea to revise. Every number in this chapter has been recomputed by an independent program, so the printed steps are trustworthy.
Figures are part of the lesson, not decoration. Each graph is drawn from the printed formula, and each schematic labels exactly the quantities the text uses. Pause at every Read the figure box and trace it with a finger before moving on.
About 1600, William Gilbert, an English physician, published the first systematic study of magnets. He showed that the Earth itself acts like a giant magnet, which is why a compass needle lines up north-south. His book collected many careful tests and separated magnetic attraction from rubbed-amber electric effects. The exact year of some of his early observations is uncertain, so this date marks the book, not the first experiment.
In 1820, Hans Christian Oersted, a Danish physicist, noticed that a current deflects a compass needle. Andre-Marie Ampere, a French physicist, then argued that permanent magnets act as if tiny current loops circulate inside them. That proposal links this chapter to the previous one: one dipole picture covers both a small coil and a small bar magnet. The sequence of weeks in 1820 is sometimes retold loosely, so treat this as the outline, not a diary.
Near the end of the nineteenth century, Pierre Curie, a French physicist, measured how the weak magnetism of many materials changes with temperature. His inverse-temperature rule still appears in this chapter. Later work on domains explained the strong memories of iron and steel: regions of aligned moments that survive after the external field is removed. The domain picture came decades after Curie, so keep the two contributions distinct.
5.1 Earth's Magnetism and Historical Dipoles
A fridge magnet holds without power, and a compass turns without touching. In this section you will learn why poles always come in pairs, and what a compass actually follows.
- Magnetic pole — one end region of a magnet, labelled north (N) or south (S).
- Compass needle — a small pivoted magnet that turns to line up with the local field.
- Magnetic moment (preview) — a vector from the S end towards the N end that measures dipole strength; defined fully in 5.2.
- Magnetisation (preview) — magnetic moment per unit volume of a material; defined fully in 5.4.
Every magnet you will meet has two ends. The end that turns towards the north is called the north-seeking pole, shortened to north pole. The opposite end is the south pole. The names describe direction-seeking behaviour, not separate substances.
Cut a bar magnet across its middle. Each piece still has a north end and a south end. Cut again and the result repeats. Grinding one piece to dust still leaves each grain with two poles. Poles always come in pairs: no cutting step isolates a lone north or south pole.
This differs from electric charge. A positive charge can sit alone. A magnetic pole cannot, as far as any experiment in this course shows. Keep that contrast ready; section 5.3 turns it into a law.
A student cuts a bar magnet into two equal pieces, then cuts each piece again the same way. Describe the poles of the final pieces.
Step 1 — goal. Track what cutting does to poles.
Step 2 — rule. Cutting divides the material; each part keeps the dipole character of the whole.
Step 3 — apply. After the first cut there are two pieces, each with N and S. After the second cut there are four pieces.
Step 4 — count. Four pieces times two poles each gives 8 poles in total, in 8 divided by 2 equals 4 pairs.
Result: There are four smaller magnets, each with N and S. Cutting multiplies dipoles; it never isolates a pole.
A compass needle is a small light magnet on a pivot. Place it in a magnetic field and it turns. Its north-seeking end settles pointing along the field direction. Friction and nearby iron can disturb it, but the alignment rule is the starting point.
A compass therefore measures direction, not strength. It tells you which way the local field points. It cannot tell you whether that field is strong or weak. Later instruments measure the magnitude; the compass only shows the line.
Near a fridge magnet the local field comes from the magnet, so the needle points at it. Far from all magnets outdoors, the needle follows the geomagnetic field. Both cases obey one rule: the N end indicates the local field direction. Compass means a direction follower, nothing more.
A compass can still mislead. A nearby iron railing or a current in a cable adds its own field, and the needle follows the sum. Surveyors check for such disturbers before trusting a bearing. A steady reading in two nearby spots builds confidence; a jump between them warns of hidden iron.
Read the figure. The left circle is the compass case. The heavy arrow through the centre is the needle; its N end points up here. The long arrow on the right is the local field B. The caption states the rule: the needle turns until N lies along B. If B rotated, the needle would follow.
A pupil breaks one magnet into three equal pieces and asks how many poles the set has. Answer with a count.
Step 1 — goal. Total poles across three pieces.
Step 2 — rule. Each piece keeps one N and one S.
Step 3 — substitute. .
Step 4 — sanity check. Three pairs means 6 poles, consistent with the four-piece result scaled down.
Result: The set has 6 poles in three pairs. More pieces mean more dipoles, never lone poles.
The names describe direction-seeking behaviour, not separate substances. Early navigators noticed one end of a lodestone turning northward and named the ends after that habit. The label stuck even after the physics moved on to moments and fields.
Bring two north ends together and they push apart. Bring two south ends together and they also push apart. Bring a north end near a south end and they pull together. These pushes and pulls are forces between whole dipoles, not between free charges.
The rule predicts what a compass does near a bar magnet. The needle is itself a small dipole. Its N end is pulled towards a nearby S pole and pushed away from a nearby N pole. The needle turns until these pulls and pushes balance along the field line.
| Ends facing each other | What you feel | Rule used |
|---|---|---|
| N and N | Push apart | Like poles repel |
| S and S | Push apart | Like poles repel |
| N and S | Pull together | Unlike poles attract |
Read the table. Each row names a facing pair, the feel, and the rule. The first two rows match; the third row is the opposite. Use it to predict the needle kick before touching any magnet.
Six words carry the whole chapter. Dipole moment measures one small magnet. Field lines map direction. Flux counts surface crossing. Magnetisation averages many moments. Susceptibility ratios the response. Domains explain memory. Each section defines its word before using it, so reread this list whenever a later page feels heavy.
Magnets attract, compasses point, and some materials remember. One dipole picture explains the first two. The third needs many dipoles added together. That is the plan of this chapter.
Section 5.2 models one small magnet completely: its field, its torque and its energy. Section 5.3 states the flux law that replaces isolated poles. Section 5.4 adds many moments into bulk quantities. Section 5.5 sorts materials by response. Each step uses only the previous steps.
Read the chapter in order the first time. The vocabulary grows sideways otherwise: moment, magnetisation, susceptibility and domains each assume the earlier term. A slow first pass saves a confused second pass.
Cover the answers. Try each question on paper first. If an answer differs from yours, find the step where your working left the printed one.
- What does the north end of a compass indicate?
- A bar magnet is cut across its middle. What happens to its poles?
- Does a compass measure field strength?
Click to reveal Quick Check answers
5.2 The Bar Magnet
A small magnet twists in a field and settles in one direction. In this section you will learn to model it as a dipole, compute its field, torque and energy, and time its swing.
- Magnetic dipole — a small magnet viewed from far away, where only its moment matters.
- Magnetic moment (m) — a vector from the S end towards the N end; its magnitude measures dipole strength, in A m².
- Axial point — a field point on the moment axis.
- Equatorial point — a field point on the midplane perpendicular to the moment axis.
- Torque — the turning effect of a field on a misaligned dipole.
- Stable orientation — the alignment a disturbed dipole returns to: m parallel to B.
Sprinkle iron dust near a bar magnet and it traces curves. Outside the magnet each curve leaves the N end and enters the S end. Inside the magnet each curve continues from S back towards N. Every line is a closed loop with no start and no end.
A tangent to a line gives the local field direction. Crowded lines in one consistent sketch mean a strong field. Lines never cross where the field direction is well defined, because one point cannot have two directions. Field line means a direction map, not a flow of anything.
Compare with electric field lines. Those may begin or end on charges. Magnetic lines have no observed source or sink, so they must close. That single difference explains much of this chapter.
Exam bar-magnet diagram: N at right, S at left, outside lines going from N to S and internal continuation from S to N.
Read the plot. The bar sits in the middle with S on the left and N on the right. Curves above and below leave N, swing round, and enter S. One straight path runs through the bar from S to N. Arrowheads outside point N to S; the return inside runs S to N.
Read the schematic. The bar shows S left and N right. Two straight arrows outside run right to left: N to S. One heavy arrow inside runs left to right and carries the label m. The bottom note fixes the convention: m points S to N even though the external field returns N to S.
Rotatable bar-magnet field loops in perpendicular planes, returning inside from S to N along x.
Read the 3D view. Four loops leave N in different tilted planes and re-enter S. Each loop closes through the bar along the axis. The vector inside marks m together with the internal B; the vectors outside mark B returning N to S. Rotate the view and every loop still closes.
An electric dipole in a uniform field feels and carries . Its far-field shape matches the magnetic case: axial twice equatorial, with the same inverse cube. Methods transfer almost unchanged between the two.
The difference is the source. Electric lines may begin or end on charges; magnetic lines never do. A lone charge exists; a lone pole does not. Use the analogy for methods, never for sources.
| Feature | Electric dipole | Magnetic dipole |
|---|---|---|
| Moment arrow | from to | m from S to N |
| Far axial field | Twice equatorial | Twice equatorial |
| Line endings | On charges | Nowhere: loops close |
| Isolated source | Charge exists | Pole not observed |
Read the table. Methods match across the first two rows; sources differ across the last two. Copy the torque and energy steps freely, but never copy a lone-pole argument.
A coil carrying current produces a similar far pattern. A flat coil of turns, current and face area has moment in A m². Place it far away and its field matches a short bar magnet of the same moment.
This equivalence needs large distance. Close to the coil you see wires; close to the magnet you see pole faces. Far away both look like one dipole. State the far-away condition beside every use of the dipole formulas.
The direction rule follows a right-hand grip. Curl the fingers with the current; the thumb gives m. For a bar magnet the same arrow runs S to N. Two sources, one arrow convention.
A solenoid has 200 turns and carries 0.25 A. Each turn encloses 4.0 cm². Find its moment, then estimate its axial field at 0.15 m, assumed far compared with its size.
Step 1 — goal. First the moment from the coil rule, then the far axial field.
Step 2 — convert the area. , so .
Step 3 — moment rule. .
Step 4 — substitute with units. .
Step 5 — compute. .
Step 6 — field rule (far axial). .
Step 7 — substitute. , so .
Step 8 — compute and convert. along m.
Step 9 — sanity check. A two-centimetre-scale coil at fifteen centimetres gives about one microtesla: far smaller than a fridge magnet, as expected.
Result: The moment is 0.02 A m² and the far axial field is about 1.19 μT along m. Convert the area before substituting; state the far condition beside the answer.
Far from a small dipole, the axial field is along m. On the equatorial midplane the field is opposite m. At equal large the axial value is exactly twice the equatorial value.
Direction matters as much as size. Axial means on the moment axis: field points with m. Equatorial means on the side midplane: field points against m. A missing direction step loses half the physics.
Both formulas need the far condition: distance large compared with the magnet size. A 5 cm magnet measured at 50 cm is ten times its size away, which counts as far. Measured at 6 cm it does not, and the formulas overreach. Write the assumed condition with the substitution.
| Point | Direction of B | Far magnitude |
|---|---|---|
| On the moment axis | Along m | |
| On the equatorial plane | Opposite m | |
| At double distance | Same direction | One-eighth of the value |
Read the table. Each row fixes a position, a direction and a size. The third row is the inverse-cube law in words: doubling r divides the field by eight. Use it for quick checks before any calculator.
A short magnet has moment 0.60 A m². Estimate B at an axial point and at an equatorial point, both at 0.30 m, each assumed far compared with the magnet size.
Step 1 — goal. Two far fields at equal distance: axial first, then equatorial.
Step 2 — axial rule. .
Step 3 — substitute. , so .
Step 4 — compute. along m.
Step 5 — equatorial rule. , opposite m.
Step 6 — compute. opposite m.
Step 7 — ratio check. : the axial value is exactly twice, as theory demands.
Result: Axial: 4.44 μT along m; equatorial: 2.22 μT opposite m. Equal far distance always gives the factor of two.
Two falling curves of dipole field strength against distance. Both drop steeply, and the axial curve stays exactly twice as high as the equatorial curve.
Read the graph. The horizontal axis is distance in metres; the vertical axis is field in microtesla for m = 0.80 A m². Both curves fall steeply because of the inverse cube. The upper curve is axial; the lower is equatorial. At 0.20 m they read 20 μT and 10 μT; verify with . At 0.40 m each has fallen to one-eighth of its 0.20 m value.
In a uniform field a dipole feels a torque . Its magnitude is , where is the angle from m to B. The torque vanishes at 0° and 180°, and peaks at 90°. Its direction always turns m towards B.
The orientation energy is . Parallel alignment gives the minimum and is stable. Antiparallel gives and is unstable: a small nudge grows instead of shrinking.
Uniformity is the condition. These two formulas assume B is the same across the dipole. In a nonuniform field there is also a net force pulling the dipole along the gradient. Do not use the torque-only picture where the field varies across the magnet. A compass needle overshoots and wobbles before settling: that wobble is the oscillation of the next paragraph, damped by pivot friction.
Fix the turning direction with a right-hand check. Point your fingers from m towards B through the smaller angle; the torque turns m that way. If m already lies along B, fingers and target coincide and no turning remains. Use this check before trusting any sign.
In a nonuniform field the dipole also feels a net force. The two ends sit in different strengths, so their pulls no longer cancel. Weak responders drift one way and strong responders the other; section 5.5 names which is which. Force needs a gradient, while torque needs only an angle.
A dipole of moment 0.50 A m² sits at 30° to a uniform field of 0.040 T. Find the torque magnitude and the energy gap between antiparallel and parallel orientations.
Step 1 — goal. Torque from the cross product, then the full orientation energy span.
Step 2 — torque rule. with .
Step 3 — substitute with units. .
Step 4 — compute. , turning m towards B.
Step 5 — energy rule. .
Step 6 — compute. .
Step 7 — sanity check. The gap is positive and far larger than the holding energy of one orientation, as the span from to must be.
Result: Torque 10 mN m towards alignment; orientation span 40 mJ. State the direction step, not just the magnitude.
Displace a small magnet slightly from parallel and release it. For a small angle, , so the restoring torque is . With rotational inertia the motion obeys .
That is simple harmonic motion with period . Damping and stray fields are neglected. The small-angle condition sits beside the formula: large swings are not harmonic.
The period formula also measures fields. Time the swing, and B follows from the known m and inertia. Stronger B means a faster swing: quadrupling B halves the period for fixed moment and inertia. Damping sets the practical limit: time several small swings and divide, because air drag and pivot friction shrink each swing.
Try each question yourself before reading the answers. Show the rule, the substitution and the units in your working.
1. Physical Setup & Coordinate Frame: A bar magnet of length and magnetic dipole moment sits along the x-axis centered at origin.
2. Governing Principle: By magnetic dipole analogy with electric dipoles (, ):
3. Algebraic Progression & Approximations: 1. On the axial line at distance from the center: Directed along the magnetic dipole moment (from South to North pole). 2. On the equatorial broadside line at distance : Directed opposite to the magnetic dipole moment . 3. Ratio: At equal distant points, .
4. Limiting Cases & Sanity Check: Falloff is (faster than inverse-square point monopole). True only in far-field limit .
- At equal large r, how do axial and equatorial field magnitudes compare?
- Which dipole orientation is stable in a uniform field, and what is its energy?
- A far-field formula is applied at the pole face. What is wrong?
Click to reveal Quick Check answers
5.3 Magnetism and Gauss's Law
Field lines never start or stop. In this section you will learn the flux law that states this, and how to apply it to closed boxes without counting every line.
- Magnetic flux — the surface integral of B over an area; its unit is the weber (Wb).
- Closed surface — a boundary with an inside and an outside, such as a box or sphere.
- Outward normal — the reference direction at each patch of a closed surface, pointing out.
- Gaussian surface (magnetism) — any imaginary closed surface used to test the flux law.
Gauss’s law for magnetism says for every closed surface. Add up the outward flux over all patches and the total is zero. Every inward contribution balances an outward one somewhere else.
The law expresses one experimental fact: no observed isolated magnetic charge exists in this classical picture. If a lone north pole existed, its field would stream outward everywhere and the total could not cancel. Zero net flux says that never happens.
The symbol matters. The circle on the integral means a closed surface. The law says nothing about an open spanning area such as a coil face. Keep the closed condition beside the law whenever you quote it.
Outward is a bookkeeping choice, not a physical arrow. Flip every normal inward and each sign flips with it, but the total stays zero. What matters is consistency: pick outward once and hold it across all six faces.
Enclose only the north end of a bar magnet in an imaginary box. Lines leave through the surrounding space. They return through the magnet body where it crosses the box wall. Inward and outward parts cancel exactly.
The enclosed region is not a region containing magnetic charge. It holds part of a dipole, and the return path passes through the same boundary. Cutting the picture with a box cannot create a monopole.
Try the same box in a uniform field. Flux enters one face and leaves the opposite face with equal magnitude. Side faces contribute nothing because B runs along them. The total is zero again, though B itself is nonzero everywhere.
An imaginary closed box shows outward flux of +0.004 Wb through five faces combined. What is the flux through the sixth face?
Step 1 — goal. The missing face flux from the total law.
Step 2 — rule. Total outward flux through a closed surface is zero.
Step 3 — substitute. .
Step 4 — compute. .
Step 5 — direction step. The negative sign means inward flow through that face.
Result: The sixth face carries -0.004 Wb (inward). No counting of lines is needed; the law fixes the total.
Read the figure. The square is the closed surface. Two arrows enter the left face and two leave the right face. One more enters the top and one leaves the bottom. Every entry has a matching exit, so the centre label reads net flux zero. A lone pole would break this pairing.
Take a uniform field of known strength through a box face of known area. With B perpendicular to the face, flux is simply strength times area. Opposite faces give equal and opposite contributions.
The side faces give zero because B runs parallel to them: no component crosses. This is the dot product at work. Perpendicular crossing counts fully; grazing counts nothing.
A uniform 0.50 T field crosses a box. One face has area 0.020 m² with B perpendicular to it. Find the flux through that face and through the opposite face.
Step 1 — goal. Flux through a face and its opposite in a uniform field.
Step 2 — rule. for perpendicular crossing.
Step 3 — substitute with units. .
Step 4 — compute. .
Step 5 — opposite face. Same magnitude, opposite sign: , so the pair sums to zero as the law requires.
Result: Each face carries 0.01 Wb, with opposite signs. The law does not imply zero B; it implies balanced flux.
Enclose the entire bar magnet in an imaginary sphere. Every field loop exits the sphere once and re-enters it once. Exits and entries pair off exactly, so the total is zero without any arithmetic.
Count poles inside as a cross-check. The sphere holds equal N and S strength, so no net source sits within. Both pictures — loop pairing and pole balance — give the same zero. Either picture alone answers the question.
A closed sphere surrounds a whole bar magnet. What is the net outward magnetic flux through the sphere?
Step 1 — goal. Net outward flux through a closed sphere.
Step 2 — rule. Gauss’s law for magnetism gives zero for every closed surface.
Step 3 — picture check. Each field loop exits once and re-enters once; the pairs cancel.
Step 4 — pole check. Equal N and S inside means no net magnetic source within.
Result: The net flux is zero. A whole dipole inside any closed surface always totals zero.
A face tilted to the field catches less flux. Only the perpendicular part of B crosses, so the flux is strength times area times the cosine of the tilt. A face edge-on to the field catches nothing at all.
Take the worked box face again: on . Tilted at 60° to the field direction, it passes : exactly half the face-on value. The cosine carries the geometry, so never drop it.
A coil face is an open surface with an edge. Flux through it can be nonzero and useful: it drives induction in the next chapter. The same holds for any spanning area of a loop.
Do not carry the zero across. Students often quote zero flux for a coil face because they remember the slogan. The slogan belongs to closed surfaces only. Ask first: does this surface have an inside and an outside?
| Surface | Net-flux rule | Example |
|---|---|---|
| Closed box or sphere | Always zero | Enclosing one pole still balances |
| Uniform field, any box | Pairs cancel face by face | In through one face, out the opposite |
| Open coil face | Can be nonzero | Linked flux drives induction later |
Read the table. Each row names a surface, its rule and one use. The first two rows obey the law; the third row escapes it honestly because the surface is open.
Work these on paper with the answers hidden. If your result disagrees with the printed one, compare the steps one by one until the paths divide.
- Does enclosing a north pole without the south end make net magnetic flux positive?
- A uniform nonzero field fills a box. What is the net outward flux?
- Name one surface whose flux can be nonzero and say why the law permits it.
Click to reveal Quick Check answers
5.4 Magnetisation and Magnetic Intensity
One dipole is simple; a spoonful of iron holds countless dipoles. In this section you will learn the bulk quantities that add them up, and the linear rule that links them.
- Magnetisation (M) — magnetic dipole moment per unit volume, in A/m.
- Magnetic field intensity (H) — the free-current part of the field description, in A/m.
- Susceptibility (χm) — the dimensionless ratio M/H for a linear isotropic material.
- Permeability (μ) — the ratio B/H for a linear material, in H/m; relative permeability μr = μ/μ₀.
A spoonful of matter holds a huge number of atomic moments. Tracking each is hopeless, so define their density: in A/m. M describes a bulk response, not one atom.
Direction follows the average. If atomic moments point randomly, M is nearly zero. If they lean one way, M points that way. Cooling, applying a field, or choosing another material changes the average.
A uniformly magnetised sample of volume 2.0 × 10⁻⁵ m³ has M = 400 A/m. Find its total moment.
Step 1 — goal. Total moment from density and volume.
Step 2 — rule. .
Step 3 — substitute with units. .
Step 4 — compute. .
Step 5 — sanity check. A centimetre-scale sample with strong magnetisation giving thousandths of A m² is reasonable.
Result: The total moment is 0.008 A m². Magnetisation times volume rebuilds the whole moment.
The total field B has two contributors: free currents and the material itself. The split is written in SI. H carries the free-current part; M carries the material part.
H earns its keep inside matter. In empty space M is zero and H is just B/μ₀. Inside a core, M can rival or exceed H, and B follows their sum. One equation, two physical sources.
For a long uniformly filled solenoid with negligible end effects, , where is turns per metre. Finite samples complicate this: the shape can produce demagnetising fields, so H inside is not always the field that would exist without the sample. Short fat samples need the largest shape corrections; long thin ones need the smallest.
Read the figure. The outer box is the winding carrying current I; the inner bar is the core. The lower arrow shows H running along the axis from the current alone. The core label reminds you that M adds to it, and B follows the sum. The bottom note warns that end effects are ignored here.
For a simple linear isotropic material, . Then . Thus and . Susceptibility is dimensionless.
This linear relation is a model, not a universal law. It fits many weakly magnetic materials well. It fails for ferromagnets, whose response is nonlinear and history dependent. State the linear condition beside every use.
A negative susceptibility means M opposes H. The material then weakens the field slightly instead of strengthening it. Section 5.5 names that behaviour diamagnetism.
A long solenoid has 400 turns per metre and carries 1.5 A. Its core is a linear material with χm = 0.020. Find H inside, then M and the relative permeability.
Step 1 — goal. H from the winding, then the material response.
Step 2 — H rule (long solenoid). .
Step 3 — substitute. .
Step 4 — M rule. along H.
Step 5 — relative permeability. .
Step 6 — meaning. The core adds only 2% to the empty field: a weak positive response, exactly what small χ means.
Result: H is 600 A/m, M is 12 A/m, and ==μr = 1.02. Small susceptibility means a small fractional change.==
Sometimes M and H are measured and the material constant is the unknown. The same linear rule rearranged gives the susceptibility as a ratio. This is how a laboratory turns two readings into one material number.
Inside a core, H = 600 A/m and M = 12 A/m point along the same line. Find χm for the linear model.
Step 1 — goal. Susceptibility from measured M and H.
Step 2 — rule. for a linear isotropic material.
Step 3 — substitute with units. .
Step 4 — compute. .
Step 5 — meaning. A small positive constant: weak paramagnetic-type response, consistent with the forward example.
Result: The susceptibility is 0.02. Forward or backward, the linear rule is the same relation.
A ratio test guards the linear claim. Measure at two different H values: if M/H drifts, the material is leaving the linear range. One ratio never proves linearity; two agreeing ratios make it plausible.
Relative permeability is handy but unit-free. Absolute permeability carries units of H/m and enters directly. Convert before substituting into field formulas.
A weakly magnetic medium has μr = 1.005. Find its absolute permeability in SI units.
Step 1 — goal. From relative to absolute permeability.
Step 2 — rule. with .
Step 3 — substitute. .
Step 4 — compute. .
Result: The permeability is 1.26 × 10⁻⁶ H/m. Keep the factor of μ₀ explicit; never add H and M directly.
| Quantity | Unit | Role |
|---|---|---|
| B (total field) | tesla (T) | What a probe feels |
| H (free-current part) | A/m | What the winding sets |
| M (material part) | A/m | What the matter adds |
| χm (susceptibility) | none | Fractional strength of M vs H |
Read the table. Each row pairs a symbol with its unit and role. B stands apart in tesla; H and M share A/m but answer different questions. The last row is their dimensionless link.
B lines always close, but H lines may begin and end on free currents. The winding is their source and sink. Inside a long solenoid they run straight along the axis; outside they spread and return.
This split explains why H follows the coil design while B follows everything. Change the winding and H changes at once. Change the core and M changes while H stays put. Designers tune each part separately.
| Situation | M vs H | Usable rule |
|---|---|---|
| Weakly magnetic core | Proportional | χm constant; μr = 1 + χm |
| Empty solenoid | M = 0 | B = μ₀H exactly |
| Ferromagnet | History dependent | No single χm; use the loop |
Read the table. Each row states when the simple proportionality holds and when it fails. The middle row is the clean reference; the last row points to section 5.5.
Cover the answers. Try each question on paper first. If an answer differs from yours, find the step where your working left the printed one.
- A linear material has negative χm. In what direction is its M relative to H?
- Why does the solenoid estimate of H need the long-coil condition?
- Which quantity lets two different-sized samples compare fairly: total moment or magnetisation?
Click to reveal Quick Check answers
5.5 Magnetic Properties of Materials
Some materials barely notice a magnet; others become magnets themselves. In this section you will learn the three responses, the temperature rule, and how to read a hysteresis loop.
- Diamagnetism — a weak induced response opposing the applied field; susceptibility small and negative.
- Paramagnetism — weak alignment of existing atomic moments with the field, broken by heat.
- Ferromagnetism — strong collective alignment within domains; nonlinear and history dependent.
- Domain — a region where atomic moments already point one way.
- Remanence — magnetisation left after the external field is removed.
- Coercivity — the reverse field needed to erase that remanence.
- Curie temperature — the temperature above which ferromagnetic order disappears.
- Hysteresis loop — the M-versus-H path that differs on the way up and down.
An applied field distorts every atomic orbit slightly. The induced change opposes the field. This happens in ordinary matter everywhere, but stronger effects usually hide it.
The susceptibility is small and negative, so relative permeability sits slightly below one. A diamagnetic sample in a nonuniform field drifts weakly towards weaker-field regions. Removal of the field erases the induced response at once.
Because the sign is negative, M points against H. No permanent moments are needed. A material with no unpaired moments shows mainly this response.
Some atoms carry permanent moments from unpaired electrons. Without a field these point randomly and cancel. A field biases them towards alignment, opposed at every step by thermal shaking.
The susceptibility is usually small and positive. A sample is drawn weakly towards stronger-field regions. When the field is removed, ordinary paramagnets lose the net alignment because heat restores randomness.
For many simple paramagnets in a suitable range, Curie’s law holds: , with in kelvin. It predicts weaker alignment at higher absolute temperature for the same field. It is not exact for every material at every temperature: state the range condition beside each use.
A simple paramagnet has susceptibility 0.006 at 250 K. Find its Curie constant, then estimate the susceptibility at 500 K.
Step 1 — goal. First the constant , then the warmed value.
Step 2 — rule. is constant in this model.
Step 3 — substitute. .
Step 4 — warmed rule. .
Step 5 — compute. .
Step 6 — meaning. Doubling the absolute temperature halves the response, exactly what thermal agitation predicts.
Result: The constant is 1.5 K and the warmed susceptibility is 0.003. Use kelvin, never Celsius, in Curie’s law.
Two falling curves of susceptibility against absolute temperature. Both follow an inverse-temperature shape, and the higher curve stays exactly twice as high.
Read the graph. The horizontal axis is absolute temperature; the vertical axis is susceptibility in model units. Both curves fall as 1/T. The upper curve has twice the constant, so it sits exactly twice as high everywhere. The caption warns that real materials follow this shape only in a limited range.
Count unpaired electrons to guess the class. All paired means diamagnetic behaviour dominates. Unpaired without collective order means paramagnetic. Unpaired with collective order means ferromagnetic. Real materials mix these, but the count usually predicts the leading term.
In iron and similar materials, interactions favour collective alignment. Atomic moments organise into domains: regions where all moments already point one way. An unmagnetised piece holds many domains whose directions cancel on a large scale.
A field grows the favoured domains and rotates others towards it. The result is a large net response from a modest field. The relation between M and H is nonlinear and depends on magnetic history: the path up differs from the path down.
Domains form as a compromise. One giant domain would leak a large external field, which costs energy. Splitting into opposing domains closes much of that field inside the piece. Walls between domains cost some energy too, so the piece settles on a domain size that balances the two. No formula is needed here; the picture explains why pieces look quiet outside while staying ordered inside.
Read the figure. The left box shows six domain arrows pointing in mixed directions: moments exist but cancel, so the piece looks unmagnetised. The right box shows six arrows all pointing right: the same moments now add. Magnetising rearranges directions; it does not create the moments.
Remove the field and some magnetisation remains: remanence. A reverse field is needed to erase it, and that field scale is the coercivity. Plotting M against H while cycling the field traces a loop.
The loop area, with the appropriate conjugate quantities, represents energy dissipated per cycle per volume. Wide loops waste more; narrow loops waste less. That is why core and magnet materials differ.
Loops are measured, not guessed. A coil winds round the sample, the current cycles H up and down, and a second coil senses M. School laboratories show only the shape; research rigs calibrate the axes. Either way, remanence and coercivity come straight off the plotted intercepts.
Illustrative magnetisation-hysteresis loop showing different paths as field intensity rises and falls.
Read the first loop. Two branches cross like a flattened lens. The upper branch is the way down; the lower branch is the way up. The nonzero vertical intercept at H = 0 is the remanence. The nonzero width is the coercive behaviour. The caption marks it as schematic only.
Hysteresis loop with three marked points: saturation at the top-right corner, remanence on the vertical axis, and coercivity on the horizontal axis.
Read the labelled loop. Three points carry exam names. Saturation sits at the top-right corner where stronger H adds little M. Remanence sits on the vertical axis at H = 0: what stays without a field. Coercivity sits on the horizontal axis at M = 0: the reverse field that erases the remanence.
Soft magnetic materials magnetise and demagnetise easily. Their narrow loops mean small energy loss per cycle. They suit electromagnet cores and transformer parts that cycle continuously.
Hard magnetic materials resist demagnetisation. Their wide loops mean large remanence and coercivity. They suit permanent magnets that must hold their field for years.
Large susceptibility alone never chooses a material. Remanence, coercivity, losses and working temperature all enter. Match the loop shape to the job, not one number to everything.
| Job | Choose | Why |
|---|---|---|
| Cycled electromagnet core | Soft | Narrow loop means small loss per cycle |
| Permanent door catch | Hard | Large remanence holds without power |
| Transformer part | Soft | Easy magnetising each half-cycle |
| Motor magnet | Hard | Large coercivity resists stray fields |
Read the table. Each row pairs a job with a material and the loop feature that matters. Cycling jobs pick narrow loops; holding jobs pick wide ones.
Above a material’s Curie temperature, long-range ferromagnetic ordering disappears. Thermal shaking beats the aligning interaction, and the response turns paramagnetic. Cooling back below restores the order.
This is a material property, not a universal number. Different ferromagnets lose order at different temperatures. Operating a magnet near its Curie point weakens it; designs stay well below. A magnet heated past its Curie point and cooled in zero field returns with random domains: unmagnetised but fully orderable again. The memory is erasable by heat alone, which is why workshops control temperature around magnetic parts.
| Class | Typical sign of χm | Response after field removal |
|---|---|---|
| Diamagnetic | Small negative | Induced net response disappears |
| Paramagnetic | Small positive | Ordinary net alignment disappears |
| Ferromagnetic | Nonlinear and history dependent | Remanence can persist |
Read the table. Each row names a class, its susceptibility sign and what survives. Only the last row keeps anything. Use the sign to sort unknown materials quickly.
A simple paramagnet has χm = 0.004 at 300 K. Estimate χm at 450 K using Curie’s law.
Step 1 — goal. Warmed susceptibility from the inverse-temperature rule.
Step 2 — rule. in this model.
Step 3 — substitute. .
Step 4 — compute. .
Step 5 — check. Higher T gives lower χ, consistent with thermal disorder winning.
Result: The warmed value is 0.002667. Kelvin in, sensible trend out.
Try each question yourself before reading the answers. Show the rule, the substitution and the units in your working.
Curves of susceptibility vs temperature. Paramagnetic falls as 1/T, diamagnetic is a constant negative line.
Key Graph Features (Slope, Intercept & Asymptotes): Paramagnetic susceptibility obeys Curie’s law , declining hyperbolically as thermal agitation disrupts dipole alignment. Diamagnetic susceptibility is negative () and strictly independent of temperature.
- Why can an apparently unmagnetised ferromagnet contain magnetised regions?
- Above its Curie temperature, what response does a ferromagnet show?
- Which loop suits a continuously cycled core, wide or narrow, and why?
Click to reveal Quick Check answers
Summary
This chapter moved from one small magnet to the behaviour of whole materials. Work down this list and tick each line you can honestly do. Revisit the named section for any line you cannot.
- Explain why cutting a magnet never isolates a single pole. (5.1)
- Draw closed field lines round a bar magnet and mark the moment from S to N. (5.2)
- Use for a coil and the far-field pair , with the direction rule. (5.2)
- Use , and with their conditions. (5.2)
- Apply to closed surfaces and separate them from open spanning areas. (5.3)
- Use , , and for linear media. (5.4)
- Estimate inside a long solenoid and explain why shape can change the internal field. (5.4)
- Sort responses into diamagnetic, paramagnetic and ferromagnetic, with the sign of susceptibility. (5.5)
- Use Curie’s law with kelvin temperatures and state its limits. (5.5)
- Read remanence and coercivity off a hysteresis loop and choose soft or hard material for a job. (5.5)
Three facts deserve a final look. Field lines of magnetism always close; cutting a magnet only makes smaller dipoles. Every dipole formula carries a condition — far field, uniform field, small angle, linear medium — and answers outside those conditions mislead. And B, H and M describe the same setup from three sides, but their units differ, so they combine only through the stated relation.
Keep this chapter’s habit: name the condition beside every rule, convert units before substituting, and verify with a limiting case. The dipole language of torque, energy and far fields returns in later physics; the fluency built here pays off there.
Points to Ponder
- Poles always come in pairs. Cutting, grinding or melting a magnet only rearranges dipoles; no operation in this chapter isolates one pole.
- A formula outside its conditions gives an answer that looks right and is wrong. Name the condition beside every rule you use.
- B, H and M describe the same setup from three sides: total field, free-current part, material part. Their units differ, so they combine only through the stated relation.
- History dependence breaks one-number descriptions. A ferromagnet needs its loop, not a single susceptibility, to predict what stays after the field is removed.
- Test each result against a limiting case: far distance, zero field, parallel alignment, high temperature. A result that fails an obvious limit is being misused.
Exercises
Master these questions in four structured tiers matching the CBSE board exam blueprint. Try every problem on paper before checking the answered solutions below.
5.MCQ.1 A magnetic needle suspended freely in a non-uniform magnetic field experiences: (a) A torque but no force; (b) A force but no torque; (c) Both a force and a torque; (d) Neither a force nor a torque.
5.MCQ.2 The relative permeability of a substance is 0.9999. The substance is: (a) Paramagnetic; (b) Diamagnetic; (c) Ferromagnetic; (d) Non-magnetic.
Each question consists of two statements: Assertion (A) and Reason (R). Choose: (a) Both A and R are true and R is correct explanation of A; (b) Both A and R are true but R is NOT correct explanation; (c) A is true, R is false; (d) A is false, R is true.
5.AR.1 Assertion (A): Gauss’s law for magnetism states that net magnetic flux through any closed surface is zero. Reason (R): Isolated magnetic monopoles do not exist in nature. Choose: (a) Both A and R are true and R is correct explanation of A; (b) Both A and R are true but R is NOT correct explanation; (c) A is true, R is false; (d) A is false, R is true.
5.AR.2 Assertion (A): Superconductors exhibit perfect diamagnetism (the Meissner effect). Reason (R): Inside a superconductor in the superconducting state, magnetic field B is identically zero and susceptibility χ = -1. Choose: (a) Both A and R are true and R is correct explanation of A; (b) Both A and R are true but R is NOT correct explanation; (c) A is true, R is false; (d) A is false, R is true.
Case-Based Assessment — Magnetic Resonance Imaging (MRI) Contrast Agents: Clinical MRI relies on strong superconducting electromagnets (1.5–3.0 T) to align hydrogen nuclear spins. Paramagnetic gadolinium chelates (Gd3+) are injected into patients to shorten proton relaxation times and enhance imaging contrast. (i) Why does gadolinium exhibit strong paramagnetism? (ii) What happens to the magnetization of a paramagnetic contrast agent if the MRI scanner temperature is lowered from 310 K to 155 K at constant magnetic field? (iii) Why can ferromagnetic materials not be used inside biological tissues for MRI?
5.1 State the direction assigned to the magnetic moment of a bar magnet.
5.2 An 80-turn coil carries 0.50 A and each turn encloses 2.0 × 10⁻³ m². Find its magnetic moment.
5.3 A short magnet has m = 1.20 A m². Estimate the axial field at r = 0.25 m, assumed a far point.
5.4 Find the equatorial field magnitude at the same distance for the same magnet, and state its direction.
5.5 A moment of 0.40 A m² makes 60° with a uniform 0.050 T field. Find the torque magnitude.
5.6 For the same moment and field, how much energy does it cost to rotate the dipole from parallel to perpendicular?
5.7 A magnet has m = 0.50 A m² and rotational inertia 8.0 × 10⁻⁶ kg m². It swings with small amplitude in B = 20 μT. Find the period.
5.8 Total outward flux through five faces of a closed box is +0.006 Wb. What is the flux through the sixth face?
5.9 Can an open surface spanning a wire loop carry nonzero magnetic flux? Explain with an example.
5.10 A sample has total moment 0.010 A m² and volume 4 × 10⁻⁵ m³. Find its magnetisation.
5.11 A linear material has χm = 0.012 and internal H = 700 A/m. Find M and μr.
5.12 Inside a core, H = 2000 A/m and M = 100 A/m along the same line. Find B.
5.13 A long solenoid has 250 turns per metre and carries 3.0 A. Estimate H inside, ignoring end effects.
5.14 A material has small negative susceptibility. Name the response class and describe what happens when the field is removed.
5.15 A simple paramagnet has χm = 0.010 at 200 K. Find its Curie constant and estimate χm at 400 K.
5.16 Two hysteresis loops use the same axis scales. Loop P is twice as wide as loop Q. Which dissipates more energy per cycle per volume, and why?
5.17 A fridge-door seal must hold its field for years without power. Choose soft or hard magnetic material and justify with two loop features.
5.18 An iron nail is stroked repeatedly with one pole of a strong magnet and then attracts pins. Explain in domain language.
5.19 A transformer core runs hot in continuous service. Why must its Curie temperature lie far above the operating temperature?
5.20 B is quoted in tesla while H and M are quoted in A/m. Explain why the statement H + M = B is wrong as written.
Answers
5.MCQ.1 (c) In a non-uniform field, forces on the two poles are unequal, producing a net translatory force as well as a rotational couple (torque).
5.MCQ.2 (b) Since , susceptibility (negative), which characterizes diamagnetic materials.
5.AR.1 (a) Both A and R are true. Magnetic poles always occur in equal and opposite dipole pairs, so any closed surface enclosing a north pole must also enclose a south pole, making net flux zero.
5.AR.2 (a) Both A and R are true, and Reason describes the Meissner effect ().
(i) The Gd3+ ion possesses seven unpaired inner 4f electrons (), giving it a large net permanent electronic magnetic dipole moment (). (ii) By Curie’s law , halving absolute temperature from 310 K to 155 K doubles the paramagnetic magnetization (). (iii) Ferromagnetic materials have enormous remanent magnetization and retain strong hysteresis; inside intense MRI field gradients, they would experience violent mechanical displacement forces, tearing biological tissue.
5.1 From its south end towards its north end. The external field returns the other way, N to S, but m itself runs S to N. Every torque and energy formula in 5.2 assumes this arrow.
5.2 . The moment scales with turns, current and area together.
5.3 . Since , along m.
5.4 , exactly half the axial value: , directed opposite m.
5.5 . So , turning m towards B.
5.6 : from to costs . Full reversal would cost twice this.
5.7 Convert: . , small-angle condition assumed.
5.8 The closed total must be zero, so , flowing inward.
5.9 Yes. A coil face links flux from a nearby magnet, and that linked flux drives induction in the next chapter. The zero law governs closed surfaces only, so openness here is a permission, not a violation.
5.10 . Two samples compare fairly through M, not through totals.
5.11 along H. . The 1.2% excess over one measures the weak response.
5.12 . H and M add only inside the bracket with μ₀ outside.
5.13 along the axis. The long-coil condition sits beside this estimate.
5.14 Diamagnetic. The induced opposition vanishes with the field, so nothing persists. A compass-style memory test finds no remanence afterwards.
5.15 . Warmed: . Absolute temperatures in kelvin throughout.
5.16 Loop P. With the appropriate conjugate quantities, loop area measures energy lost per cycle per volume, and the wider loop encloses the larger area. That is why cycled cores use narrow loops.
5.17 Hard material. It offers large remanence, so field stays with no current, and large coercivity, so stray reverse fields do not erase it.
5.18 Stroking grows domains aligned with the stroke and rotates others towards it. The nail gains net M and acts as a weak temporary magnet.
5.19 Near or above the Curie point, ferromagnetic order collapses and the response turns weakly paramagnetic. The core would stop guiding flux efficiently, so designs keep a wide margin. Heat plus load leaves no room for a marginal material.
5.20 The two sides carry different units. The correct SI link is : only inside the bracket, scaled by μ₀, do H and M combine into B.